US13 NC42 NC561 over SCLRR
Map
Coordinates:
+36.28150, -76.9891436°16'53" N, 76°59'21" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US13 NC42 NC561 over SCLRR |
Structure number: | 000000000910031 |
Old structure number: | 000000000091031 (from 1992 edition) |
Location: | 0.5 MI.S.JCT.NC561 |
Purpose: | Carries highway and pedestrian walkway over railroad |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 44.0 ft. [13.4 m] |
Total length: | 133.9 ft. [40.8 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 34.5 ft. [10.5 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1938 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 12,000 [as of 2015] |
Truck traffic: | 7% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 50.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Fair | Fair | Fair | 12000 | 50.9 |
September 2015 | Fair | Fair | Fair | Fair | 12000 | 50.9 |
September 2013 | Fair | Fair | Fair | Fair | 12000 | 50.9 |
September 2011 | Poor | Fair | Fair | Poor | 11000 | 35.3 |
September 2009 | Poor | Fair | Fair | Poor | 14000 | 30.0 |
September 2007 | Poor | Fair | Fair | Poor | 7400 | 33.3 |
October 2005 | Poor | Fair | Fair | Poor | 7400 | 33.3 |
July 2003 | Fair | Fair | Fair | Fair | 14000 | 48.8 |
August 2001 | Fair | Fair | Fair | Fair | 13000 | 49.1 |
November 1999 | Fair | Fair | Fair | Fair | 13000 | 52.2 |
December 1997 | Fair | Fair | Fair | Fair | 13000 | 55.1 |
November 1995 | Fair | Fair | Fair | Fair | 13000 | 54.9 |
July 1994 | Fair | Fair | Satisfactory | Fair | 12000 | 49.2 |
November 1991 | Fair | Fair | Satisfactory | Fair | 10400 | 52.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 685 | 216 | 466 | 3 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 3,081 | 729 | 2,352 | 0 | 0 |
Wearing Surfaces | sq. ft. | 3,475 | 3,379 | 48 | 48 | 0 |
Substructure |
Reinforced Concrete Column | each | 10 | 3 | 7 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 16 | 16 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 120 | 71 | 41 | 8 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 270 | 234 | 21 | 15 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 1,532 | 252 | 1,280 | 0 | 0 |