SR1303 over VINE SWAMP
Map
Coordinates:
+35.14537, -77.5077935°08'43" N, 77°30'28" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1303 over VINE SWAMP |
Structure number: | 000000001030004 |
Old structure number: | 000000000103004 (from 1992 edition) |
Location: | 0.6 MI.S.OF JCT.SR1305 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 17.1 ft. [5.2 m] |
Total length: | 53.2 ft. [16.2 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 29.2 ft. [8.9 m] |
Owner: | State Highway Agency [01] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Wood or timber [7] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 340 [as of 2013] |
Truck traffic: | 6% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 80.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Fair | Fair | Satisfactory | Good | 340 | 80.7 |
October 2016 | Fair | Fair | Satisfactory | Good | 340 | 80.7 |
October 2014 | Fair | Fair | Fair | Good | 340 | 70.6 |
October 2012 | Fair | Fair | Fair | Good | 340 | 70.6 |
October 2010 | Fair | Satisfactory | Fair | Satisfactory | 520 | 68.6 |
October 2008 | Poor | Satisfactory | Poor | Poor | 430 | 52.5 |
October 2006 | Fair | Good | Satisfactory | Satisfactory | 460 | 78.6 |
September 2004 | Fair | Good | Satisfactory | Satisfactory | 460 | 78.6 |
October 2002 | Good | Good | Good | Good | 480 | 78.6 |
November 2000 | Good | Good | Good | Good | 440 | 78.6 |
October 1998 | Good | Good | Good | Good | 470 | 78.6 |
October 1996 | Good | Good | Good | Good | 350 | 79.7 |
October 1994 | Good | Good | Good | Good | 300 | 78.5 |
October 1992 | Good | Good | Good | Good | 250 | 78.7 |
October 1990 | Good | Good | Good | Good | 200 | 78.8 |