SR1114 over LITTLE HELL CREEK
Map
Coordinates:
+34.97954, -77.2719434°58'46" N, 77°16'19" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1114 over LITTLE HELL CREEK |
Structure number: | 000000001030080 |
Location: | 2.1 MI.W.JCT.US17 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 28.9 ft. [8.8 m] |
Total length: | 30.8 ft. [9.4 m] |
Roadway width between curbs: | 24.3 ft. [7.4 m] |
Deck width edge-to-edge: | 25.6 ft. [7.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1962 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Main span material: | Prestressed concrete [5] |
Main span design: | Channel beam [22] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 320 [as of 2012] |
Truck traffic: | 6% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 60.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Fair | Fair | Fair | 320 | 60.4 |
November 2016 | Fair | Fair | Fair | Fair | 310 | 60.4 |
November 2014 | Fair | Fair | Fair | Fair | 310 | 60.4 |
November 2012 | Fair | Fair | Fair | Fair | 310 | 64.8 |
November 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 310 | 76.6 |
November 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 340 | 76.6 |
November 2006 | Fair | Satisfactory | Satisfactory | Satisfactory | 320 | 66.2 |
November 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 320 | 66.2 |
November 2002 | Fair | Good | Good | Satisfactory | 300 | 66.2 |
February 2001 | Fair | Very Good | Very Good | Satisfactory | 300 | 66.2 |
November 1998 | Fair | Very Good | Very Good | Satisfactory | 280 | 66.2 |
November 1990 | Fair | Very Good | Very Good | Satisfactory | 300 | 73.4 |