Share:

SR1318 over BIG GOVERNERS CREEK

Map

Coordinates:
+35.47341, -79.35660
35°28'24" N, 79°21'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR1318 over BIG GOVERNERS CREEK
Structure number:000000001050052
Old structure number:000000000105052 (from 1992 edition)
Location:2.7 MI. W. JCT. SR1007
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:44.0 ft. [13.4 m]
Total length:180.1 ft. [54.9 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:28.5 ft. [8.7 m]
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:230 [as of 2011]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:80.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairGoodGoodSatisfactory23080.1
March 2015GoodGoodGoodGood23080.1
March 2013FairSatisfactoryGoodGood23080.1
March 2011FairSatisfactoryVery GoodGood30079.7
March 2009FairSatisfactoryVery GoodGood30079.7
February 2007FairSatisfactoryVery GoodSatisfactory27079.7
February 2005FairSatisfactoryVery GoodSatisfactory32073.7
February 2003FairSatisfactoryVery GoodSatisfactory32073.7
March 2001FairSatisfactoryVery GoodSatisfactory27076.6
February 1999FairSatisfactoryVery GoodSatisfactory23081.2
January 1997FairSatisfactoryVery GoodSatisfactory25081.2
January 1995FairSatisfactoryVery GoodSatisfactory23078.1
June 1993FairSatisfactoryVery GoodSatisfactory20073.9
May 1991FairSatisfactoryVery GoodSatisfactory10079.8