NC11 BYP. SBL over SOUTH WEST CREEK
Map
Coordinates:
+35.14890, -77.7062235°08'56" N, 77°42'22" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NC11 BYP. SBL over SOUTH WEST CREEK |
Structure number: | 000000001070176 |
Location: | .4 MI. N. JCT. SR114 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 59.1 ft. [18.0 m] |
Total length: | 687.0 ft. [209.4 m] |
Roadway width between curbs: | 30.2 ft. [9.2 m] |
Deck width edge-to-edge: | 33.1 ft. [10.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 2003 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 12 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,000 [as of 2013] |
Truck traffic: | 7% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 82.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Satisfactory | Good | Good | 4000 | 82.5 |
March 2016 | Good | Good | Good | Good | 4000 | 82.5 |
March 2014 | Fair | Good | Satisfactory | Good | 3950 | 82.5 |
March 2012 | Good | Good | Good | Good | 3550 | 82.6 |
March 2010 | Good | Good | Very Good | Very Good | 4100 | 82.5 |
June 2008 | Good | Good | Very Good | Very Good | 4100 | 82.5 |
May 2006 | Good | Good | Very Good | Very Good | 4100 | 82.5 |
March 2004 | Good | Very Good | Very Good | Very Good | 4300 | 82.5 |
June 2003 | Good | Very Good | Very Good | Very Good | 3000 | 82.7 |