US64 EBL over GARDNERS CREEK
Map
Coordinates:
+35.81141, -76.9329835°48'41" N, 76°55'59" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US64 EBL over GARDNERS CREEK |
Structure number: | 000000001170238 |
Location: | 0.5 MI.E. OF JCT.SR1511 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 58.1 ft. [17.7 m] |
Total length: | 180.1 ft. [54.9 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 41.3 ft. [12.6 m] |
Skew angle: | 26° |
Owner: | State Highway Agency [01] |
Year built: | 1992 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,700 [as of 2013] |
Truck traffic: | 14% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 98.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Fair | Satisfactory | Satisfactory | 3700 | 98.7 |
May 2016 | Fair | Fair | Satisfactory | Satisfactory | 3700 | 98.7 |
May 2014 | Fair | Satisfactory | Good | Good | 3500 | 99.7 |
May 2012 | Good | Good | Good | Good | 3700 | 99.7 |
June 2010 | Good | Good | Good | Good | 3750 | 99.7 |
June 2008 | Good | Good | Good | Good | 3750 | 99.7 |
September 2006 | Good | Good | Good | Good | 3950 | 99.6 |
February 2004 | Good | Good | Good | Good | 3450 | 99.7 |
April 2002 | Good | Good | Good | Good | 3700 | 99.7 |
April 2000 | Good | Good | Good | Good | 3450 | 99.7 |
August 1998 | Good | Good | Good | Good | 2750 | 99.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 915 | 915 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 7,440 | 7,348 | 90 | 2 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 162 | 135 | 6 | 21 | 0 |
Prestressed Concrete Pile | each | 34 | 18 | 16 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 190 | 171 | 18 | 1 | 0 |
Joints |
Pourable Joint | linear ft. | 168 | 160 | 0 | 8 | 0 |
Bearings |
Elastomeric Bearing | each | 30 | 30 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 360 | 0 | 0 | 360 | 0 |