US13/64 EB over COLLIE SWAMP
Map
Coordinates:
+35.83987, -77.1969235°50'24" N, 77°11'49" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US13/64 EB over COLLIE SWAMP |
Structure number: | 000000001170254 |
Location: | 1.3MI.W. OF JCT.US64 ALT |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 47.9 ft. [14.6 m] |
Total length: | 270.0 ft. [82.3 m] |
Roadway width between curbs: | 38.4 ft. [11.7 m] |
Deck width edge-to-edge: | 42.0 ft. [12.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1999 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 6 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Slab [01] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: July 2008
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,500 [as of 2007] |
Truck traffic: | 14% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 100.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2008 | Fair | Good | Satisfactory | Very Good | 4500 | 100.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 3,122 | 3,122 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 9,352 | 9,352 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 10,492 | 10,415 | 77 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 1 | 1 | 0 | 0 | 0 |
Steel Pile | each | 50 | 43 | 7 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 321 | 321 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 195 | 195 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 168 | 168 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 542 | 485 | 53 | 4 | 0 |