NC46 over I95
Map
Coordinates:
+36.46851, -77.6111436°28'07" N, 77°36'40" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NC46 over I95 |
Structure number: | 000000001310041 |
Location: | 0.3 MI W. OF JCT SR 1235 |
Purpose: | Carries highway over highway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 80.1 ft. [24.4 m] |
Total length: | 297.9 ft. [90.8 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 33.5 ft. [10.2 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 36° |
Owner: | State Highway Agency [01] |
Year built: | 1960 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 4 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,400 [as of 2013] |
Truck traffic: | 12% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 68.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Satisfactory | Satisfactory | Fair | 6400 | 68.0 |
March 2015 | Fair | Satisfactory | Satisfactory | Fair | 6400 | 68.0 |
March 2013 | Fair | Good | Fair | Fair | 5600 | 68.0 |
March 2011 | Fair | Satisfactory | Fair | Fair | 6400 | 68.0 |
March 2009 | Fair | Satisfactory | Fair | Fair | 6400 | 68.0 |
March 2007 | Fair | Fair | Satisfactory | Fair | 6600 | 67.0 |
May 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 3000 | 79.0 |
March 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 2800 | 79.0 |
January 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 4700 | 79.0 |
May 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 4200 | 79.0 |
January 1989 | Fair | Very Good | Good | Satisfactory | 4000 | 77.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,192 | 1,189 | 3 | 0 | 0 |
Steel Protective Coating | sq. ft. | 13,544 | 13,544 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 9,962 | 9,855 | 107 | 0 | 0 |
Wearing Surfaces | sq. ft. | 8,344 | 8,342 | 2 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 9 | 6 | 3 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 100 | 93 | 2 | 5 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 21 | 21 | 0 | 0 | 0 |
Prestressed Concrete Pile | each | 14 | 14 | 0 | 0 | 0 |
Reinforced Concrete Pile | each | 3 | 3 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 178 | 145 | 22 | 11 | 0 |
Joints |
Pourable Joint | linear ft. | 185 | 140 | 28 | 17 | 0 |
Bearings |
Movable Bearing | each | 30 | 0 | 30 | 0 | 0 |
Steel Protective Coating | sq. ft. | 30 | 0 | 30 | 0 | 0 |
Other Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2 | 0 | 2 | 0 | 0 |
Bridge Rail |
Other Material Bridge Rail | linear ft. | 596 | 590 | 6 | 0 | 0 |