NC35 over POTECASI CREEK
Map
Coordinates:
+36.37559, -77.2359236°22'32" N, 77°14'09" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NC35 over POTECASI CREEK |
Structure number: | 000000001310075 |
Old structure number: | 000000000131075 (from 1992 edition) |
Location: | 0.5MI.N.JCT.SR1501 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 20.0 ft. [6.1 m] |
Total length: | 153.9 ft. [46.9 m] |
Roadway width between curbs: | 34.1 ft. [10.4 m] |
Deck width edge-to-edge: | 36.4 ft. [11.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1967 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 7 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,500 [as of 2013] |
Truck traffic: | 7% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 78.5 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Fair | Fair | Fair | 1500 | 78.5 |
March 2015 | Fair | Fair | Fair | Fair | 1500 | 78.5 |
March 2013 | Fair | Fair | Fair | Fair | 1700 | 78.3 |
March 2011 | Fair | Fair | Fair | Fair | 1700 | 78.1 |
March 2009 | Fair | Satisfactory | Satisfactory | Good | 1600 | 90.4 |
March 2007 | Fair | Fair | Fair | Satisfactory | 2400 | 73.8 |
January 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 2100 | 86.5 |
January 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 2000 | 87.7 |
February 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 1800 | 87.8 |
March 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 1800 | 87.8 |
February 1997 | Fair | Satisfactory | Satisfactory | Satisfactory | 1900 | 87.7 |
January 1995 | Fair | Satisfactory | Satisfactory | Satisfactory | 1500 | 85.5 |
January 1993 | Fair | Satisfactory | Satisfactory | Satisfactory | 1900 | 85.1 |
February 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 1900 | 85.1 |