US117 over WASHINGTON CREEK
Map
Coordinates:
+34.68282, -77.9429934°40'58" N, 77°56'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US117 over WASHINGTON CREEK |
Structure number: | 000000001410228 |
Old structure number: | 000000000141228 (from 1992 edition) |
Location: | 0.1 MI S. OF JCT. I-40 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 7.9 ft. [2.4 m] |
Total length: | 24.9 ft. [7.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1983 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,300 [as of 2013] |
Truck traffic: | 7% of total traffic |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Culvert condition: | Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 87.2 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
October 2018 | Fair | 5 out of 10 | 3300 | 87.2 |
October 2016 | Fair | 5 out of 10 | 3300 | 87.2 |
October 2014 | Good | 7 out of 10 | 3300 | 98.5 |
October 2012 | Fair | 5 out of 10 | 3600 | 86.0 |
October 2010 | Fair | 5 out of 10 | 3300 | 85.2 |
December 2008 | Fair | 5 out of 10 | 3500 | 85.1 |
December 2006 | Fair | 5 out of 10 | 3700 | 85.0 |
December 2004 | Fair | 5 out of 10 | 3700 | 85.0 |
November 2002 | Fair | 5 out of 10 | 3600 | 85.0 |
November 2000 | Fair | 5 out of 10 | 3900 | 86.9 |
May 1999 | Fair | 5 out of 10 | 3900 | 86.9 |
August 1997 | Fair | 5 out of 10 | 2600 | 87.6 |
July 1995 | Fair | 5 out of 10 | 2600 | 87.7 |
June 1993 | Fair | 5 out of 10 | 2600 | 87.7 |
June 1991 | Fair | 5 out of 10 | 2600 | 87.7 |