+35.21477, -82.1854935°12'53" N, 82°11'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-26 WBL over N. PACOLET RIVER SR1516 |
Structure number: | 000000001490048 |
Location: | 2.2 MI.E.JCT.NC108 |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 68.9 ft. [21.0 m] |
Total length: | 325.1 ft. [99.1 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 43.0 ft. [13.1 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 43° |
Owner: | State Highway Agency [01] |
Year built: | 1966 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 6 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: September 2009
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,500 [as of 2008] |
Truck traffic: | 23% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 75.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 13500 | 75.3 |
August 1999 | Fair | Satisfactory | Very Good | Fair | 10500 | 62.4 |
July 1991 | Fair | Satisfactory | Good | Fair | 7800 | 60.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,233 | 910 | 1,314 | 9 | 0 |
Steel Protective Coating | sq. ft. | 20,058 | 16,835 | 835 | 2,388 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 13,992 | 12,932 | 414 | 646 | 0 |
Substructure |
Reinforced Concrete Column | each | 20 | 19 | 1 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 135 | 131 | 2 | 2 | 0 |
Steel Pile | each | 1 | 1 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 418 | 394 | 15 | 9 | 0 |
Joints |
Compression Joint | linear ft. | 118 | 94 | 0 | 6 | 18 |
Assembly with Seal | each | 295 | 239 | 28 | 28 | 0 |
Bearings |
Movable Bearing | each | 42 | 0 | 42 | 0 | 0 |
Steel Protective Coating | sq. ft. | 42 | 0 | 31 | 11 | 0 |
Fixed Bearing | each | 42 | 0 | 42 | 0 | 0 |
Steel Protective Coating | sq. ft. | 42 | 0 | 33 | 9 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 658 | 573 | 85 | 0 | 0 |