Share:

SR1105 over SCUPPERNONG RIVER

Map

Coordinates:
+35.87781, -76.33739
35°52'40" N, 76°20'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR1105 over SCUPPERNONG RIVER
Structure number:000000001770021
Old structure number:000000000177021 (from 1992 edition)
Location:0.5MI.W. OF JCT.SR.1109
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:34.1 ft. [10.4 m]
Total length:245.1 ft. [74.7 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:28.5 ft. [8.7 m]
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:200 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:70.9
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018FairFairFairFair20070.9
February 2016FairFairFairFair14070.8
February 2014FairFairFairFair14070.8
February 2012FairFairFairFair14070.8
February 2010FairFairFairSatisfactory16070.4
February 2008FairFairFairSatisfactory24066.0
March 2006FairSatisfactorySatisfactorySatisfactory26073.5
March 2004FairSatisfactorySatisfactorySatisfactory16078.2
March 2002FairSatisfactorySatisfactorySatisfactory39073.3
March 2000FairSatisfactorySatisfactorySatisfactory25078.1
April 1998FairSatisfactorySatisfactorySatisfactory25078.1
February 1996FairSatisfactorySatisfactorySatisfactory25078.1
March 1994FairSatisfactorySatisfactorySatisfactory16077.7
February 1992FairSatisfactoryGoodSatisfactory25073.4