Share:

COUNTY ROAD over CEDAR CREEK

Map

Coordinates:
+46.05041, -102.22719
46°03'01" N, 102°13'38" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD over CEDAR CREEK
Structure number:000000001137170
Location:19 EAST 3 NORTH HETTINGER
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:55.1 ft. [16.8 m]
Total length:56.1 ft. [17.1 m]
Roadway width between curbs:18.0 ft. [5.5 m]
Deck width edge-to-edge:20.0 ft. [6.1 m]
Owner:County Highway Agency [02]
Year built:2009
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:3 [as of 2017]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:71.5
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$137,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairSatisfactoryGoodSatisfactory371.5
September 2015FairGoodGoodSatisfactory371.5
November 2013FairGoodGoodSatisfactory371.5
September 2011FairGoodGoodSatisfactory371.5
January 2010FairGoodGoodSatisfactory371.5
January 2008PoorPoorPoorSerious322.5
March 2006PoorPoorPoorSerious322.5
January 2004PoorPoorPoorSerious322.5
December 2001PoorPoorPoorSerious322.5
February 2000PoorPoorPoorSerious322.5
January 1998PoorPoorPoorSerious322.5
December 1995PoorPoorPoorSerious322.5
April 1994PoorPoorPoorSerious328.7
January 1992PoorPoorPoorSerious328.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.221002210
Steel Protective Coatingsq. ft.999009990
Substructure
Steel Columneach40040
Steel Protective Coatingsq. ft.999000999
Timber Abutmentlinear ft.4204200
Steel Pier Caplinear ft.2102100
Steel Protective Coatingsq. ft.999000999
Timber Pier Caplinear ft.2102100
Deck
Timber Decksq. ft.1,11483527900
Bridge Rail