COLL 7881 over WIGLE CREEK
Map
Coordinates:
+42.30600, -96.4968142°18'22" N, 96°29'49" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COLL 7881 over WIGLE CREEK |
Structure number: | C002202510P |
Location: | .7S OF HOMER |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 109.9 ft. [33.5 m] |
Total length: | 111.9 ft. [34.1 m] |
Roadway width between curbs: | 30.5 ft. [9.3 m] |
Deck width edge-to-edge: | 32.8 ft. [10.0 m] |
Skew angle: | 10° |
Owner: | County Highway Agency [02] |
Year built: | 2004 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 375 [as of 1998] |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 98.3 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Good | Very Good | Very Good | Very Good | 375 | 98.3 |
August 2016 | Good | Excellent | Excellent | Excellent | 375 | 98.3 |
August 2014 | Good | Excellent | Excellent | Excellent | 375 | 98.3 |
August 2012 | Good | Excellent | Excellent | Excellent | 375 | 99.9 |
September 2010 | Good | Excellent | Excellent | Excellent | 375 | 99.9 |
August 2008 | Good | Excellent | Excellent | Excellent | 375 | 99.9 |
August 2006 | Good | Excellent | Excellent | Excellent | 375 | 99.9 |
October 2004 | Good | Excellent | Excellent | Excellent | 375 | 99.9 |
September 2002 | Poor | Very Good | Poor | Fair | 375 | 27.4 |
October 2000 | Fair | Very Good | Fair | Fair | 415 | 40.8 |
September 1998 | Fair | Very Good | Fair | Fair | 415 | 40.8 |
September 1996 | Fair | Very Good | Fair | Fair | 415 | 30.5 |
October 1994 | Fair | Very Good | Satisfactory | Satisfactory | 415 | 41.8 |
October 1992 | Fair | Very Good | Satisfactory | Satisfactory | 415 | 48.0 |
November 1989 | Poor | Satisfactory | Poor | Fair | 415 | 16.4 |