HANOVER ST(CR 616) over N. BRANCH RANCOCAS CREEK
Map
Coordinates:
+39.96995, -74.6841639°58'12" N, 74°41'03" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HANOVER ST(CR 616) over N. BRANCH RANCOCAS CREEK |
Structure number: | 03E4550 |
Location: | 0.5 MI N OF CR530&616 JCT |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 100.1 ft. [30.5 m] |
Total length: | 104.0 ft. [31.7 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 30.8 ft. [9.4 m] |
Owner: | County Highway Agency [02] |
Year built: | 1932 |
Year reconstructed: | 1977 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Open Grating [3] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 12,538 [as of 2017] |
Truck traffic: | 3% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of replacement [2] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 6.0 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $3,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Poor | Fair | Serious | Satisfactory | 12538 | 6.0 |
November 2015 | Poor | Satisfactory | Serious | Satisfactory | 15934 | 7.0 |
December 2013 | Poor | Satisfactory | Serious | Satisfactory | 15776 | 7.0 |
January 2012 | Poor | Satisfactory | Serious | Satisfactory | 15466 | 7.0 |
January 2010 | Poor | Satisfactory | Serious | Satisfactory | 15209 | 7.0 |
November 2007 | Poor | Satisfactory | Serious | Satisfactory | 14770 | 7.0 |
December 2005 | Poor | Satisfactory | Serious | Satisfactory | 7800 | 7.0 |
September 2005 | Poor | Satisfactory | Serious | Satisfactory | 7650 | 7.0 |
September 2003 | Poor | Satisfactory | Serious | Satisfactory | 7650 | 7.0 |
August 2003 | Poor | Satisfactory | Poor | Satisfactory | 7500 | 18.0 |
June 2001 | Poor | Satisfactory | Poor | Satisfactory | 13800 | 17.8 |
April 1999 | Poor | Satisfactory | Poor | Satisfactory | 13300 | 17.8 |
April 1997 | Poor | Satisfactory | Poor | Satisfactory | 12327 | 21.2 |
May 1995 | Poor | Satisfactory | Poor | Satisfactory | 11968 | 8.5 |
May 1993 | Poor | Satisfactory | Poor | Satisfactory | 11968 | 8.5 |
February 1991 | Poor | Satisfactory | Poor | Satisfactory | 23630 | 8.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 870 | 806 | 0 | 45 | 19 |
Steel Protective Coating | sq. ft. | 4,500 | 0 | 3,200 | 1,300 | 0 |
Steel Truss | linear ft. | 204 | 0 | 184 | 20 | 0 |
Steel Protective Coating | sq. ft. | 1,500 | 0 | 750 | 750 | 0 |
Steel Floor Beam | linear ft. | 210 | 0 | 95 | 90 | 25 |
Steel Protective Coating | sq. ft. | 1,250 | 0 | 250 | 1,000 | 0 |
Steel Gusset Plate | each | 36 | 0 | 34 | 2 | 0 |
Steel Protective Coating | sq. ft. | 650 | 0 | 450 | 175 | 25 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 128 | 87 | 36 | 5 | 0 |
Deck |
Open Grid Deck | sq. ft. | 3,255 | 3,250 | 5 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,600 | 0 | 5,600 | 0 | 0 |
Joints |
Assembly with Seal | each | 62 | 0 | 50 | 12 | 0 |
Bearings |
Movable Bearing | each | 2 | 0 | 2 | 0 | 0 |
Fixed Bearing | each | 2 | 0 | 2 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 208 | 208 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 100 | 100 | 0 | 0 | 0 |