Share:

SOUT H ARLINGTONAV over ORANGE IND.TRACK (ABAND)

Map

Coordinates:
+40.78026, -74.19631
40°46'49" N, 74°11'47" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SOUT H ARLINGTONAV over ORANGE IND.TRACK (ABAND)
Structure number:0755160
Location:0.21 MI S OF WATSESSING A
Route classification:Collector (Urban) [17]
Length of largest span:46.9 ft. [14.3 m]
Total length:110.9 ft. [33.8 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:50.9 ft. [15.5 m]
Skew angle:19°
Owner:Unknown [80]
Year built:1931
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,000 [as of 2017]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:59.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactorySatisfactory500059.6
October 2015FairSatisfactorySatisfactorySatisfactory500059.6
October 2013FairSatisfactorySatisfactorySatisfactory500060.6
October 2011FairSatisfactorySatisfactorySatisfactory477560.6
July 2009PoorFairSatisfactoryPoor477533.5
May 2007PoorFairSatisfactoryPoor468233.6
May 2005PoorFairSatisfactorySerious459014.9
April 2003PoorSatisfactorySatisfactoryPoor450034.7
February 2001PoorSatisfactorySatisfactoryPoor450034.5
January 1999PoorSatisfactorySatisfactoryPoor440034.6
January 1997PoorSatisfactorySatisfactoryPoor420045.4
November 1994PoorSatisfactorySatisfactoryPoor400047.2
October 1992PoorSatisfactorySatisfactoryPoor300021.3
July 1990FairSatisfactorySatisfactoryFair300042.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,11091002000
Steel Protective Coatingsq. ft.1,11091020000
Deck
Reinforced Concrete Decksq. ft.5,6283,1382,2252650
Substructure
Steel Columneach1010000
Steel Protective Coatingsq. ft.6005406000
Reinforced Concrete Pier Walllinear ft.108981000
Reinforced Concrete Abutmentlinear ft.106426400
Steel Pier Caplinear ft.108103050
Steel Protective Coatingsq. ft.9008604000
Joints
Compression Jointlinear ft.3030000
Bearings
Enclosed/Concealed Bearingeach6060000
Fixed Bearingeach6060000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.222222000
Steel Protective Coatingsq. ft.1,3001,300000