Share:

SOUTH MAIN STREET. over RARITAN VALLEY LINE

Map

Coordinates:
+40.68792, -75.19775
40°41'17" N, 75°11'52" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SOUTH MAIN STREET. over RARITAN VALLEY LINE
Structure number:2160166
Location:.4M E OF DELAWARE RIVER
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:137.1 ft. [41.8 m]
Total length:149.0 ft. [45.4 m]
Roadway width between curbs:36.1 ft. [11.0 m]
Deck width edge-to-edge:37.1 ft. [11.3 m]
Vertical clearance above deck:14.8 ft. [4.5 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:45°
Owner:Other State Agencies [21]
Year built:1914
Year reconstructed:1992
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,407 [as of 2017]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairSatisfactoryFairSatisfactory1140777.7
March 2015FairSatisfactoryFairSatisfactory1470076.6
April 2013FairSatisfactoryFairSatisfactory1442076.6
May 2011FairSatisfactoryFairSatisfactory1414076.7
May 2009FairGoodFairSatisfactory1386076.7
May 2007FairGoodFairSatisfactory1358076.8
May 2005FairGoodFairSatisfactory1331176.8
February 2003FairGoodFairSatisfactory1279377.9
March 2001FairGoodFairSatisfactory1279378.8
December 1998FairGoodFairSatisfactory1242078.9
October 1996FairVery GoodFairGood1150078.8
September 1994FairVery GoodFairGood1150081.0
May 1994PoorSeriousFairFair1096053.2
October 1991PoorSeriousFairFair1096053.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Stringerlinear ft.1,2371,13710000
Steel Protective Coatingsq. ft.2,5772,5017600
Deck
Reinforced Concrete Decksq. ft.5,5135,513000
Wearing Surfacessq. ft.5,3645,227117200
Superstructure
Steel Trusslinear ft.29801481500
Steel Protective Coatingsq. ft.10,49810,19830000
Steel Floor Beamlinear ft.6600595650
Steel Protective Coatingsq. ft.3,6583,04861000
Steel Gusset Plateeach44202040
Steel Protective Coatingsq. ft.4003901000
Substructure
Reinforced Concrete Abutmentlinear ft.1047414160
Joints
Compression Jointlinear ft.104590045
Bearings
Movable Bearingeach42020
Fixed Bearingeach41120
Pot Bearingeach41300
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.29823750101
Steel Protective Coatingsq. ft.1,7881,788000