NM-108 over RUNNING WATER DRAW
Map
Coordinates:
+34.49976, -103.0555434°29'59" N, 103°03'20" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NM-108 over RUNNING WATER DRAW |
Structure number: | 000000000005726 |
Location: | 7.7 MI N JCT US-60/TEXICO |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 24.9 ft. [7.6 m] |
Total length: | 174.9 ft. [53.3 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 24.0 ft. [7.3 m] |
Owner: | State Highway Agency [01] |
Year built: | 1956 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 7 |
Main spans material: | Concrete [1] |
Main spans design: | Channel beam [22] |
Deck type: | Other [9] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,907 [as of 2017] |
Truck traffic: | 22% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 55.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $283,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Fair | Fair | Satisfactory | 1907 | 55.9 |
August 2016 | Fair | Fair | Fair | Satisfactory | 418 | 68.0 |
August 2015 | Fair | Fair | Fair | Satisfactory | 442 | 67.9 |
August 2014 | Fair | Fair | Fair | Satisfactory | 442 | 67.9 |
August 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 437 | 80.2 |
August 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 444 | 80.2 |
March 2012 | Fair | Fair | Fair | Fair | 431 | 68.0 |
March 2011 | Fair | Fair | Fair | Fair | 2015 | 53.2 |
March 2010 | Fair | Fair | Fair | Fair | 2049 | 53.0 |
March 2009 | Fair | Fair | Fair | Fair | 2049 | 53.0 |
March 2008 | Fair | Fair | Fair | Fair | 2081 | 52.9 |
March 2006 | Fair | Fair | Fair | Fair | 2134 | 52.7 |
March 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 2204 | 66.3 |
March 2002 | Fair | Satisfactory | Satisfactory | Satisfactory | 975 | 69.4 |
February 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 303 | 79.6 |
September 1997 | Fair | Satisfactory | Satisfactory | Satisfactory | 283 | 79.7 |
October 1995 | Fair | Good | Satisfactory | Satisfactory | 277 | 77.4 |
January 1994 | Fair | Good | Satisfactory | Satisfactory | 267 | 73.4 |
January 1992 | Fair | Good | Good | Satisfactory | 275 | 73.3 |
January 1990 | Fair | Satisfactory | Satisfactory | Good | 208 | 78.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,400 | 0 | 960 | 440 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 4,206 | 0 | 4,206 | 0 | 0 |
Wearing Surfaces | sq. ft. | 3,680 | 0 | 3,680 | 0 | 0 |
Substructure |
Steel Column | each | 18 | 0 | 18 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,127 | 0 | 1,127 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 56 | 0 | 56 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 168 | 0 | 168 | 0 | 0 |
Joints |
Open Joint | linear ft. | 132 | 0 | 132 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 350 | 0 | 350 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,313 | 0 | 1,313 | 0 | 0 |