Share:

US 95A over WALKER RVR

Map

Coordinates:
+38.99395, -119.17881
38°59'38" N, 119°10'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 95A over WALKER RVR
Structure number:B 600
Location:YERINGTON
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:38.1 ft. [11.6 m]
Total length:129.9 ft. [39.6 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:38.1 ft. [11.6 m]
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:4,500 [as of 2014]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:96.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017GoodGoodGoodGood450096.5
March 2015GoodGoodGoodGood450096.5
March 2013GoodGoodGoodGood470094.4
August 2011GoodGoodGoodGood470093.5
April 2009FairGoodGoodSatisfactory470093.5
April 2007FairGoodGoodSatisfactory470093.5
March 2005FairGoodGoodSatisfactory490093.4
September 2003FairGoodGoodSatisfactory500093.4
April 2001FairGoodGoodSatisfactory500092.4
October 2000FairGoodGoodSatisfactory500090.4
May 1999FairGoodGoodSatisfactory435090.7
May 1997FairGoodGoodSatisfactory395590.9
April 1995GoodGoodGoodGood378091.0
May 1993GoodGoodGoodGood378091.0
April 1991GoodGoodGoodGood349091.1
April 1990GoodGoodGoodGood349091.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.152014660
Reinforced Concrete Abutmentlinear ft.7676000
Reinforced Concrete Pile Cap/Footinglinear ft.44000
Reinforced Concrete Pileeach4848000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2601808000
Deck
Reinforced Concrete Slabsq. ft.4,9494,3463902130