Share:

OFF RMP I 80W over SPRR

Map

Coordinates:
+40.98257, -117.72014
40°58'57" N, 117°43'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OFF RMP I 80W over SPRR
Structure number:G 872R
Location:WINNEMUCCA
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:118.1 ft. [36.0 m]
Total length:255.9 ft. [78.0 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:31.5 ft. [9.6 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:40°
Owner:State Highway Agency [01]
Year built:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:950 [as of 2014]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:98.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,062,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017GoodGoodGoodGood95098.0
August 2015GoodGoodGoodGood95098.0
August 2013GoodGoodGoodGood110098.0
August 2011GoodGoodGoodGood110097.9
August 2009GoodGoodGoodGood110097.9
August 2007GoodGoodGoodGood110097.9
August 2005GoodGoodGoodGood67097.9
September 2003GoodGoodGoodGood57598.0
August 2001GoodGoodGoodGood62597.9
August 1999GoodGoodGoodGood62597.9
October 1998PoorGoodGoodSerious62553.9
January 1998PoorGoodGoodSerious73053.9
July 1995FairGoodGoodFair67086.9
September 1993FairGoodFairGood67086.9
July 1991GoodGoodVery GoodVery Good95597.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.7686749400
Deck
Reinforced Concrete Decksq. ft.8,0617,25580600
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.8282000
Reinforced Concrete Pile Cap/Footinglinear ft.150150000
Timber Pileeach4848000
Reinforced Concrete Pier Caplinear ft.7878000
Joints
Compression Jointlinear ft.82671500
Bearings
Elastomeric Bearingeach64020
Fixed Bearingeach66000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.495495000
Reinforced Concrete Bridge Raillinear ft.51230320540