RTE 9B over GREAT CHAZY RIVER
Map
Coordinates:
+44.94235, -73.4090244°56'32" N, 73°24'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RTE 9B over GREAT CHAZY RIVER |
Structure number: | 000000001006270 |
Location: | IN VILL OF COOPERSVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 109.9 ft. [33.5 m] |
Total length: | 115.2 ft. [35.1 m] |
Roadway width between curbs: | 29.2 ft. [8.9 m] |
Deck width edge-to-edge: | 32.2 ft. [9.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1930 |
Year reconstructed: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Poor |
Status: | Posted for other load-capacity restriction [R] |
Average daily traffic: | 2,782 [as of 2015] |
Truck traffic: | 11% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 31.3 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $4,976,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Poor | Good | Serious | Fair | 2782 | 31.3 |
August 2015 | Poor | Good | Poor | Fair | 2799 | 44.4 |
August 2013 | Poor | Good | Poor | Fair | 2128 | 55.4 |
August 2011 | Poor | Good | Poor | Fair | 2150 | 55.4 |
September 2009 | Fair | Good | Fair | Fair | 2132 | 71.8 |
October 2007 | Fair | Good | Fair | Fair | 2439 | 71.6 |
September 2005 | Fair | Good | Satisfactory | Fair | 2769 | 61.2 |
October 2003 | Fair | Very Good | Satisfactory | Fair | 2769 | 61.2 |
September 2001 | Good | Very Good | Very Good | Good | 2769 | 73.5 |
September 1999 | Good | Very Good | Very Good | Good | 2059 | 84.0 |
June 1997 | Fair | Very Good | Good | Satisfactory | 2248 | 84.9 |
October 1995 | Fair | Very Good | Satisfactory | Fair | 2248 | 73.6 |
August 1993 | Fair | Very Good | Satisfactory | Satisfactory | 2320 | 84.8 |
November 1991 | Fair | Very Good | Satisfactory | Satisfactory | 1589 | 67.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 1,029 | 860 | 108 | 60 | 1 |
Steel Protective Coating | sq. ft. | 4,503 | 4,503 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 3,580 | 3,573 | 0 | 7 | 0 |
Wearing Surfaces | sq. ft. | 3,351 | 3,344 | 0 | 7 | 0 |
Superstructure |
Steel Truss | linear ft. | 229 | 209 | 8 | 12 | 0 |
Steel Protective Coating | sq. ft. | 5,833 | 5,833 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 252 | 136 | 56 | 60 | 0 |
Steel Protective Coating | sq. ft. | 2,092 | 2,092 | 0 | 0 | 0 |
Steel Gusset Plate | each | 14 | 5 | 5 | 3 | 1 |
Steel Protective Coating | sq. ft. | 406 | 406 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 120 | 0 | 120 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 4 | 4 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 229 | 229 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,716 | 1,716 | 0 | 0 | 0 |