RTE 23A over SPRUCE CREEK
Map
Coordinates:
+42.19127, -74.0707142°11'29" N, 74°04'15" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RTE 23A over SPRUCE CREEK |
Structure number: | 000000001017980 |
Location: | JCT 23A & KAATERSKILL FLS |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 30.8 ft. [9.4 m] |
Roadway width between curbs: | 24.3 ft. [7.4 m] |
Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1920 |
Year reconstructed: | 1992 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Other [9] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,357 [as of 2015] |
Truck traffic: | 9% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 59.2 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $918,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Satisfactory | Fair | Fair | 2357 | 59.2 |
May 2015 | Fair | Satisfactory | Fair | Fair | 2703 | 51.7 |
June 2013 | Fair | Satisfactory | Fair | Satisfactory | 2703 | 58.5 |
June 2011 | Fair | Satisfactory | Satisfactory | Fair | 4000 | 58.2 |
June 2009 | Fair | Satisfactory | Satisfactory | Fair | 3570 | 59.0 |
July 2007 | Fair | Satisfactory | Fair | Fair | 3043 | 60.1 |
July 2005 | Poor | Satisfactory | Poor | Fair | 3558 | 39.9 |
December 2004 | Fair | Satisfactory | Fair | Fair | 3307 | 59.5 |
July 2003 | Fair | Satisfactory | Fair | Fair | 3513 | 59.1 |
August 2001 | Fair | Satisfactory | Fair | Fair | 3513 | 59.1 |
June 1999 | Fair | Very Good | Very Good | Satisfactory | 3509 | 71.4 |
June 1997 | Fair | Good | Fair | Satisfactory | 3574 | 59.0 |
June 1995 | Fair | Satisfactory | Satisfactory | Fair | 3290 | 59.4 |
June 1993 | Fair | Very Good | Satisfactory | Fair | 3550 | 58.9 |
August 1991 | Fair | Very Good | Very Good | Fair | 4195 | 62.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 180 | 0 | 177 | 3 | 0 |
Steel Protective Coating | sq. ft. | 770 | 0 | 684 | 77 | 9 |
Deck |
Reinforced Concrete Deck | sq. ft. | 867 | 0 | 867 | 0 | 0 |
Wearing Surfaces | sq. ft. | 756 | 0 | 756 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 68 | 0 | 53 | 15 | 0 |
Masonry Abutment | linear ft. | 96 | 0 | 89 | 7 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 20 | 0 | 20 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 116 | 0 | 116 | 0 | 0 |
Bearings |
Movable Bearing | each | 12 | 0 | 0 | 12 | 0 |
Steel Protective Coating | sq. ft. | 48 | 0 | 0 | 0 | 48 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 62 | 0 | 62 | 0 | 0 |
Steel Protective Coating | sq. ft. | 670 | 0 | 670 | 0 | 0 |