Share:

174TH STREET over RTE I895, BRONX RIVER, A

Map

Coordinates:
+40.83540, -73.88209
40°50'07" N, 73°52'56" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:174TH STREET over RTE I895, BRONX RIVER, A
Structure number:000000002066720
Location:JCT I95 & I278
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:190.0 ft. [57.9 m]
Total length:765.1 ft. [233.2 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:62.0 ft. [18.9 m]
Vertical clearance above deck:15.4 ft. [4.7 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:City or Municipal Highway Agency [04]
Year built:1909
Year reconstructed:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: November 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:14,970 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:51.4
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$41,251,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2018PoorFairSatisfactoryPoor1497051.4
August 2016FairFairSatisfactoryFair1509367.8
July 2014FairFairSatisfactoryFair908664.4
August 2012PoorSatisfactorySatisfactoryPoor908652.8
August 2010PoorSatisfactorySatisfactoryPoor908652.8
October 2008PoorSatisfactorySatisfactoryPoor908652.8
October 2006FairSatisfactorySatisfactoryFair908669.0
October 2004PoorSatisfactorySatisfactoryPoor908652.8
July 2002PoorSatisfactorySatisfactoryPoor1183952.6
June 2000PoorSatisfactorySatisfactoryPoor1183952.6
November 1998FairSatisfactorySatisfactorySatisfactory1183980.0
November 1996PoorPoorPoorPoor1044257.3
November 1994PoorPoorPoorPoor1013448.9
September 1992PoorPoorPoorPoor1013448.9
November 1990PoorPoorSeriousSerious1013429.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,0731,948111140
Steel Protective Coatingsq. ft.33,93528,1675,76800
Steel Stringerlinear ft.6,3856,26212300
Steel Protective Coatingsq. ft.29,86028,5561,30400
Deck
Reinforced Concrete Decksq. ft.45,94228,37511,6765,8910
Wearing Surfacessq. ft.31,04219,31811,2604640
Superstructure
Steel Trusslinear ft.38028476200
Steel Protective Coatingsq. ft.38,00024,51011,4001,900190
Steel Floor Beamlinear ft.1,8641,76191120
Steel Protective Coatingsq. ft.28,64827,1431,49870
Steel Gusset Plateeach2215700
Steel Protective Coatingsq. ft.4624006200
Substructure
Steel Columneach1614020
Steel Protective Coatingsq. ft.4003841600
Reinforced Concrete Columneach42110
Reinforced Concrete Pier Walllinear ft.946410200
Reinforced Concrete Abutmentlinear ft.96731580
Reinforced Concrete Pier Caplinear ft.8484000
Joints
Compression Jointlinear ft.3757312715025
Bearings
Movable Bearingeach2811863
Steel Protective Coatingsq. ft.964133220
Fixed Bearingeach84310
Steel Protective Coatingsq. ft.2111901
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,5511,551000
Steel Protective Coatingsq. ft.6,1975,63756000
Reinforced Concrete Bridge Raillinear ft.320320000