BLEECKER STREET over CAYADUTTA CREEK
Map
Coordinates:
+43.06484, -74.3472143°03'53" N, 74°20'50" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | BLEECKER STREET over CAYADUTTA CREEK |
Structure number: | 000000002204340 |
Location: | CITY OF GLOVERSVILLE |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 10.8 ft. [3.3 m] |
Total length: | 25.9 ft. [7.9 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 50.5 ft. [15.4 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1914 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Slab [01] |
Deck type: | Not applicable [N] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 895 [as of 2016] |
Truck traffic: | 4% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 55.9 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $449,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Fair | Fair | Fair | 895 | 55.9 |
April 2017 | Fair | Fair | Fair | Fair | 902 | 55.9 |
April 2016 | Fair | Fair | Fair | Fair | 912 | 55.9 |
April 2015 | Fair | Fair | Fair | Fair | 796 | 53.9 |
April 2014 | Fair | Fair | Fair | Fair | 796 | 53.9 |
May 2013 | Fair | Fair | Fair | Fair | 843 | 53.9 |
April 2012 | Fair | Fair | Fair | Fair | 860 | 53.9 |
April 2011 | Fair | Fair | Fair | Satisfactory | 860 | 53.9 |
April 2010 | Fair | Fair | Fair | Fair | 855 | 57.0 |
April 2009 | Fair | Fair | Fair | Fair | 855 | 57.0 |
April 2008 | Fair | Fair | Fair | Fair | 855 | 57.0 |
April 2007 | Fair | Fair | Fair | Fair | 855 | 57.0 |
April 2006 | Poor | Fair | Fair | Poor | 981 | 42.9 |
April 2005 | Poor | Fair | Fair | Poor | 981 | 42.9 |
May 2004 | Poor | Fair | Fair | Poor | 981 | 42.9 |
May 2002 | Poor | Fair | Fair | Poor | 981 | 42.8 |
May 2001 | Poor | Fair | Fair | Poor | 981 | 42.8 |
July 2000 | Poor | Fair | Fair | Poor | 1069 | 41.7 |
July 1999 | Poor | Fair | Serious | Serious | 1069 | 24.5 |
July 1998 | Poor | Satisfactory | Satisfactory | Serious | 1069 | 25.5 |
September 1997 | Poor | - | Serious | Serious | 1069 | 25.5 |
August 1996 | Poor | - | Serious | Serious | 1069 | 30.1 |
July 1995 | Poor | - | Serious | Serious | 300 | 36.8 |
August 1994 | Poor | - | Serious | Serious | 300 | 35.4 |
July 1993 | Poor | - | Fair | Serious | 300 | 35.4 |
July 1992 | Poor | - | Fair | Serious | 300 | 35.4 |
August 1991 | Poor | - | Fair | Serious | 300 | 34.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 102 | 0 | 102 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 28 | 24 | 4 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 102 | 90 | 12 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 63 | 0 | 63 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 26 | 0 | 20 | 6 | 0 |
Steel Protective Coating | sq. ft. | 134 | 0 | 0 | 40 | 94 |
Deck |
Reinforced Concrete Slab | sq. ft. | 718 | 572 | 0 | 146 | 0 |
Wearing Surfaces | sq. ft. | 666 | 400 | 259 | 0 | 7 |