UNION STREET over GOWANUS CANAL
Map
Coordinates:
+40.67954, -73.9885040°40'46" N, 73°59'19" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | UNION STREET over GOWANUS CANAL |
Structure number: | 000000002240270 |
Location: | OVER GOWANUS CANAL |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 55.8 ft. [17.0 m] |
Total length: | 107.0 ft. [32.6 m] |
Roadway width between curbs: | 35.1 ft. [10.7 m] |
Deck width edge-to-edge: | 46.3 ft. [14.1 m] |
Vertical clearance below bridge: | 3.3 ft. [1.0 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1905 |
Year reconstructed: | 1962 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Movable - Bascule [16] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,556 [as of 2016] |
Truck traffic: | 4% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 35.6 |
Recommended work: | Bridge deck replacement with only incidental widening. [37] |
Estimated cost of work: | $12,457,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Poor | Satisfactory | Serious | Fair | 4556 | 35.6 |
August 2016 | Fair | Satisfactory | Fair | Fair | 4571 | 56.9 |
August 2014 | Fair | Satisfactory | Fair | Fair | 4452 | 53.5 |
August 2012 | Fair | Satisfactory | Fair | Fair | 4452 | 53.5 |
September 2010 | Fair | Satisfactory | Fair | Fair | 4452 | 53.5 |
October 2008 | Fair | Satisfactory | Fair | Fair | 4452 | 54.5 |
August 2006 | Fair | Satisfactory | Fair | Fair | 4452 | 54.5 |
August 2004 | Fair | Satisfactory | Fair | Fair | 4452 | 54.5 |
June 2002 | Fair | Satisfactory | Fair | Fair | 4463 | 53.2 |
August 2000 | Fair | Satisfactory | Fair | Fair | 4463 | 53.2 |
October 1998 | Poor | Satisfactory | Poor | Fair | 4463 | 36.8 |
September 1996 | Poor | Fair | Poor | Poor | 4091 | 37.0 |
September 1994 | Poor | Fair | Poor | Poor | 9418 | 31.5 |
June 1992 | Poor | Poor | Poor | Poor | 9418 | 29.0 |
October 1990 | Poor | Fair | Poor | Poor | 9418 | 46.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 212 | 0 | 82 | 130 | 0 |
Steel Protective Coating | sq. ft. | 1,696 | 0 | 992 | 704 | 0 |
Steel Stringer | linear ft. | 1,190 | 0 | 770 | 420 | 0 |
Steel Protective Coating | sq. ft. | 3,570 | 0 | 1,806 | 1,764 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,897 | 0 | 4,866 | 31 | 0 |
Wearing Surfaces | sq. ft. | 3,710 | 0 | 3,159 | 551 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 415 | 0 | 360 | 55 | 0 |
Steel Protective Coating | sq. ft. | 2,866 | 0 | 2,416 | 450 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 92 | 0 | 92 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 92 | 0 | 0 | 92 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 56 | 0 | 56 | 0 | 0 |
Joints |
Open Joint | linear ft. | 46 | 0 | 46 | 0 | 0 |
Other Joint | linear ft. | 92 | 0 | 0 | 92 | 0 |
Bearings |
Fixed Bearing | each | 18 | 0 | 6 | 12 | 0 |
Steel Protective Coating | sq. ft. | 36 | 0 | 8 | 28 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 212 | 0 | 212 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,696 | 0 | 1,696 | 0 | 0 |