BROAD STREET over 907G SB-907K Ramp, BRONX
Map
Coordinates:
+40.92711, -73.8398340°55'38" N, 73°50'23" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | BROAD STREET over 907G SB-907K Ramp, BRONX |
Structure number: | 000000003348370 |
Location: | 1.3 MI E DUNWOODIE |
Purpose: | Carries highway and pedestrian walkway over highway, waterway, and railroad |
Route classification: | Local (Urban) [19] |
Length of largest span: | 93.8 ft. [28.6 m] |
Total length: | 582.0 ft. [177.4 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 40.0 ft. [12.2 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | County Highway Agency [02] |
Year built: | 1923 |
Year reconstructed: | 1985 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 6 |
Main spans material: | Concrete [1] |
Main spans design: | Arch - Deck [11] |
Deck type: | Not applicable [N] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 77.9 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $24,596,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Satisfactory | Good | Satisfactory | - | 77.9 |
July 2015 | Fair | - | Satisfactory | Satisfactory | - | 77.9 |
August 2013 | Fair | - | Satisfactory | Satisfactory | 11746 | 55.1 |
August 2011 | Fair | - | Satisfactory | Fair | 11746 | 45.2 |
August 2009 | Fair | - | Satisfactory | Fair | 13721 | 48.6 |
August 2007 | Fair | - | Satisfactory | Fair | 11746 | 49.2 |
September 2005 | Fair | - | Satisfactory | Fair | 11746 | 45.9 |
May 2003 | Fair | - | Satisfactory | Fair | 11746 | 45.9 |
September 2001 | Fair | - | Satisfactory | Fair | 11746 | 44.9 |
December 1999 | Fair | - | Satisfactory | Fair | 11746 | 47.1 |
November 1997 | Poor | - | Fair | Poor | 11746 | 29.4 |
November 1995 | Poor | - | Poor | Poor | 11746 | 25.9 |
December 1993 | Poor | - | Poor | Poor | 16000 | 23.0 |
August 1991 | Poor | - | Poor | Poor | 16000 | 27.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 180 | 180 | 0 | 0 | 0 |
Reinforced Concrete Stringer | linear ft. | 57 | 57 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 25,680 | 21,393 | 4,152 | 135 | 0 |
Wearing Surfaces | sq. ft. | 15,510 | 13,320 | 2,190 | 0 | 0 |
Superstructure |
Reinforced Concrete Arch | linear ft. | 534 | 234 | 291 | 9 | 0 |
Reinforced Concrete Floor Beam | linear ft. | 180 | 180 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 7 | 7 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 160 | 94 | 66 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 101 | 52 | 49 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 99 | 16 | 81 | 2 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 986 | 986 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6,250 | 5,560 | 690 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 120 | 120 | 0 | 0 | 0 |