SCARSDALE ROAD over BRONX RIVER
Map
Coordinates:
+40.95171, -73.8291140°57'06" N, 73°49'45" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SCARSDALE ROAD over BRONX RIVER |
Structure number: | 000000003348570 |
Location: | AT TUCKAHOE |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 48.9 ft. [14.9 m] |
Total length: | 55.1 ft. [16.8 m] |
Roadway width between curbs: | 30.5 ft. [9.3 m] |
Deck width edge-to-edge: | 49.5 ft. [15.1 m] |
Skew angle: | 26° |
Owner: | County Highway Agency [02] |
Year built: | 1911 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Concrete [1] |
Main span design: | Arch - Deck [11] |
Deck type: | Not applicable [N] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,837 [as of 2010] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 41.8 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $1,368,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Fair | Satisfactory | 6837 | 41.8 |
August 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 7291 | 57.4 |
August 2013 | Fair | - | Satisfactory | Satisfactory | 7291 | 57.4 |
September 2011 | Fair | - | Satisfactory | Satisfactory | 6574 | 57.5 |
July 2009 | Fair | - | Satisfactory | Satisfactory | 10590 | 57.1 |
August 2007 | Fair | - | Satisfactory | Satisfactory | 6574 | 57.5 |
August 2005 | Fair | - | Satisfactory | Satisfactory | 6574 | 57.5 |
October 2003 | Fair | - | Satisfactory | Satisfactory | 6574 | 57.5 |
August 2001 | Fair | - | Satisfactory | Satisfactory | 6574 | 57.1 |
October 1999 | Fair | - | Satisfactory | Good | 6574 | 57.1 |
September 1997 | Fair | - | Fair | Satisfactory | 6574 | 39.3 |
October 1995 | Fair | - | Fair | Fair | 7500 | 47.1 |
October 1993 | Fair | - | Fair | Fair | 7500 | 46.1 |
June 1991 | Fair | - | Fair | Fair | 7500 | 52.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Arch | linear ft. | 51 | 0 | 49 | 2 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 100 | 100 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 470 | 450 | 20 | 0 | 0 |