BENSON AVENUE over EAST FORK OF MILL CREEK
Map
Coordinates:
+39.22398, -84.4489639°13'26" N, 84°26'56" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | BENSON AVENUE over EAST FORK OF MILL CREEK |
Structure number: | 3137600 |
Location: | AT REA-LOC LINE |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 75.1 ft. [22.9 m] |
Total length: | 75.1 ft. [22.9 m] |
Roadway width between curbs: | 30.8 ft. [9.4 m] |
Deck width edge-to-edge: | 30.8 ft. [9.4 m] |
Owner: | County Highway Agency [02] |
Year built: | 1909 |
Year reconstructed: | 1992 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Concrete [1] |
Main span design: | Arch - Thru [12] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,131 [as of 2015] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 74.5 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Estimated cost of work: | $38,417,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Good | Good | Satisfactory | 4131 | 74.5 |
August 2017 | Fair | Good | Good | Satisfactory | 4131 | 74.5 |
March 2016 | Fair | Good | Good | Satisfactory | 4131 | 74.5 |
May 2015 | Fair | Good | Good | Satisfactory | 6500 | 71.6 |
March 2013 | Fair | Good | Good | Satisfactory | 6500 | 71.6 |
November 2011 | Fair | Good | Good | Satisfactory | 6500 | 47.0 |
March 2010 | Fair | Good | Good | Satisfactory | 6500 | 47.0 |
July 2009 | Fair | Very Good | Very Good | Satisfactory | 6500 | 47.0 |
February 2008 | Fair | Very Good | Very Good | Satisfactory | 6500 | 57.7 |
August 2007 | Fair | Very Good | Very Good | Satisfactory | 6500 | 70.4 |
September 2006 | Fair | Very Good | Very Good | Satisfactory | 6500 | 70.4 |
July 2005 | Fair | Very Good | Very Good | Satisfactory | 6500 | 70.4 |
September 2004 | Fair | Good | Good | Satisfactory | 6500 | 70.4 |
September 2003 | Good | Very Good | Very Good | Good | 6500 | 70.4 |
August 2001 | Good | Very Good | Very Good | Good | 6500 | 70.4 |
September 2000 | Good | Very Good | Very Good | Good | 6500 | 49.7 |
October 1999 | Good | Very Good | Excellent | Good | 6500 | 49.7 |
September 1997 | Good | Excellent | Excellent | Good | 6500 | 49.7 |
July 1996 | Good | Excellent | Excellent | Good | 6500 | 49.7 |
June 1995 | Good | Excellent | Excellent | Good | 6500 | 46.7 |
July 1994 | Good | Excellent | Excellent | Good | 6500 | 46.7 |
April 1993 | Good | Very Good | Very Good | Good | 6500 | 46.7 |
August 1991 | Poor | Fair | Poor | Poor | 6500 | 28.1 |