US101 (HWY 9) over Half Viaduct
Map
Coordinates:
+45.74427, -123.9597345°44'39" N, 123°57'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US101 (HWY 9) over Half Viaduct |
Structure number: | 01954A 009 4066 |
Location: | 015 MI S SHORT SANDS BCH |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 15.1 ft. [4.6 m] |
Total length: | 44.9 ft. [13.7 m] |
Roadway width between curbs: | 28.9 ft. [8.8 m] |
Deck width edge-to-edge: | 23.6 ft. [7.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 1940 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,400 [as of 2017] |
Truck traffic: | 16% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 63.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Good | Good | Good | Good | 4400 | 63.4 |
October 2016 | Good | Good | Good | Good | 3500 | 65.9 |
October 2014 | Good | Good | Good | Good | 3700 | 65.3 |
October 2012 | Good | Good | Good | Good | 3700 | 65.3 |
October 2010 | Good | Good | Good | Good | 4200 | 64.0 |
October 2008 | Good | Good | Good | Good | 4200 | 66.9 |
October 2006 | Good | Good | Good | Good | 4900 | 64.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 90 | 90 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 930 | 930 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 675 | 675 | 0 | 0 | 0 |
Substructure |
Other Material Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 47 | 47 | 0 | 0 | 0 |
Joints |
Other Joint | linear ft. | 22 | 22 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 2 | 0 | 0 | 0 |
Bridge Rail |
Masonry Bridge Rail | linear ft. | 45 | 45 | 0 | 0 | 0 |