US 30 (HWY 123) over WILLAMETTE RV/UPRR & P&W
Map
Coordinates:
+45.58602, -122.7627845°35'10" N, 122°45'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 30 (HWY 123) over WILLAMETTE RV/UPRR & P&W |
Structure number: | 06497 123 00091 |
Location: | 0.6 MI NW PORTLAND CC |
Purpose: | Carries highway over highway, waterway, and railroad |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 1207.1 ft. [367.9 m] |
Total length: | 3606.8 ft. [1099.3 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 50.5 ft. [15.4 m] |
Vertical clearance above deck: | 17.1 ft. [5.2 m] |
Vertical clearance below bridge: | 203.4 ft. [62.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1931 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Suspension [13] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: February 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 18,300 [as of 2017] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 66.4 |
Recommended work: | Widening of existing bridge or other major structure without deck rehabilitation or replacement [33] |
Estimated cost of work: | $30,459,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 18300 | 66.4 |
February 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 19900 | 65.8 |
January 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 20700 | 65.5 |
June 2011 | Fair | Good | Good | Satisfactory | 20700 | 65.5 |
September 2009 | Fair | Good | Good | Satisfactory | 20700 | 58.0 |
June 2008 | Fair | Good | Good | Satisfactory | 25071 | 58.0 |
June 2006 | Fair | Good | Satisfactory | Fair | 24100 | 50.0 |
June 2004 | Fair | Good | Fair | Fair | 24100 | 50.0 |
June 2002 | Poor | Poor | Fair | Fair | 24300 | 47.0 |
June 2000 | Poor | Poor | Fair | Fair | 23000 | 44.0 |
June 1998 | Fair | Fair | Satisfactory | Satisfactory | 18800 | 57.0 |
June 1996 | Fair | Fair | Satisfactory | Satisfactory | 18800 | 57.0 |
June 1994 | Fair | Satisfactory | Satisfactory | Satisfactory | 18800 | 56.0 |
June 1992 | Fair | Satisfactory | Satisfactory | Satisfactory | 18800 | 56.0 |
June 1990 | Fair | Satisfactory | Satisfactory | Satisfactory | 17900 | 56.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 43,194 | 35,293 | 7,450 | 451 | 0 |
Steel Protective Coating | sq. ft. | 103,609 | 63,553 | 34,936 | 4,658 | 462 |
Deck |
Reinforced Concrete Deck | sq. ft. | 184,129 | 136,640 | 41,853 | 5,636 | 0 |
Concrete Protective Coating | sq. ft. | 18,413 | 18,413 | 0 | 0 | 0 |
Superstructure |
Steel Truss | linear ft. | 7,141 | 6,290 | 774 | 77 | 0 |
Steel Protective Coating | sq. ft. | 568,393 | 560,695 | 6,282 | 708 | 708 |
Steel Main Cable | linear ft. | 5,414 | 5,373 | 20 | 21 | 0 |
Steel Protective Coating | sq. ft. | 17,725 | 17,725 | 0 | 0 | 0 |
Steel Secondary Cable | each | 212 | 0 | 210 | 2 | 0 |
Steel Protective Coating | sq. ft. | 214 | 109 | 97 | 6 | 2 |
Steel Floor Beam | linear ft. | 12,207 | 10,925 | 1,030 | 252 | 0 |
Steel Protective Coating | sq. ft. | 86,341 | 76,077 | 8,634 | 1,295 | 335 |
Steel Pin or Pin & Hangar Assembly | each | 22 | 21 | 0 | 1 | 0 |
Steel Protective Coating | sq. ft. | 22 | 22 | 0 | 0 | 0 |
Steel Gusset Plate | each | 2,008 | 1,365 | 7 | 636 | 0 |
Steel Protective Coating | sq. ft. | 225,900 | 178,472 | 44,980 | 2,248 | 200 |
Substructure |
Steel Column | each | 19 | 15 | 4 | 0 | 0 |
Steel Protective Coating | sq. ft. | 126,782 | 126,394 | 331 | 55 | 2 |
Reinforced Concrete Column | each | 27 | 13 | 11 | 3 | 0 |
Reinforced Concrete Abutment | linear ft. | 1,419 | 1,405 | 10 | 4 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 8 | 0 | 8 | 0 | 0 |
Steel Pier Cap | linear ft. | 208 | 208 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 7,800 | 5,324 | 2,476 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 507 | 0 | 507 | 0 | 0 |
Compression Joint | linear ft. | 248 | 0 | 248 | 0 | 0 |
Assembly with Seal | each | 101 | 0 | 101 | 0 | 0 |
Bearings |
Movable Bearing | each | 44 | 38 | 4 | 2 | 0 |
Steel Protective Coating | sq. ft. | 134 | 35 | 72 | 25 | 2 |
Fixed Bearing | each | 32 | 27 | 5 | 0 | 0 |
Steel Protective Coating | sq. ft. | 176 | 44 | 97 | 33 | 2 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 7,248 | 6,887 | 361 | 0 | 0 |
Steel Protective Coating | sq. ft. | 44,726 | 42,039 | 2,236 | 361 | 90 |
Reinforced Concrete Bridge Rail | linear ft. | 454 | 409 | 45 | 0 | 0 |