US 26 (HWY 47) over N FORK NECANICUM RIVER
Map
Coordinates:
+45.90810, -123.8067645°54'29" N, 123°48'24" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 26 (HWY 47) over N FORK NECANICUM RIVER |
Structure number: | 06524 047 00707 |
Location: | 071 MI SE CANNON BCH JCT |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 56.8 ft. [17.3 m] |
Total length: | 100.1 ft. [30.5 m] |
Roadway width between curbs: | 34.5 ft. [10.5 m] |
Deck width edge-to-edge: | 36.1 ft. [11.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1942 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 9,500 [as of 2016] |
Truck traffic: | 11% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 72.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Fair | Satisfactory | Satisfactory | 9500 | 72.5 |
May 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 8400 | 73.5 |
May 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 6200 | 73.5 |
May 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 6200 | 73.5 |
May 2009 | Fair | Satisfactory | Good | Satisfactory | 5900 | 73.4 |
May 2007 | Fair | Satisfactory | Good | Fair | 6000 | 63.4 |
April 2005 | Poor | Satisfactory | Good | Poor | 6000 | 47.5 |
April 2004 | Fair | Satisfactory | Very Good | Fair | 5900 | 62.1 |
May 2003 | Fair | Satisfactory | Very Good | Fair | 5900 | 62.1 |
May 2001 | Fair | Satisfactory | Very Good | Fair | 5800 | 62.1 |
May 1999 | Fair | Good | Very Good | Satisfactory | 5700 | 73.1 |
May 1997 | Good | Good | Very Good | Good | 3700 | 77.5 |
May 1995 | Good | Good | Very Good | Good | 3700 | 60.7 |
May 1993 | Good | Good | Very Good | Good | 3700 | 60.7 |
May 1991 | Good | Good | Very Good | Good | 4250 | 69.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 200 | 200 | 0 | 0 | 0 |
Reinforced Concrete Floor Beam | linear ft. | 288 | 288 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 2 | 2 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 72 | 72 | 0 | 0 | 0 |
Joints |
Other Joint | linear ft. | 69 | 0 | 0 | 0 | 69 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 203 | 197 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 667 | 583 | 84 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 3,620 | 1,200 | 2,420 | 0 | 0 |