COLUMBIA BLVD over MILTON CREEK
Map
Coordinates:
+45.85868, -122.8239745°51'31" N, 122°49'26" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COLUMBIA BLVD over MILTON CREEK |
Structure number: | 13757A111101082 |
Location: | 002 MI W JCT C1111/HWY30 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 51.8 ft. [15.8 m] |
Total length: | 126.0 ft. [38.4 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 41.7 ft. [12.7 m] |
Skew angle: | 40° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1958 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,966 [as of 2010] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 53.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Satisfactory | Satisfactory | Fair | 4966 | 53.4 |
May 2015 | Fair | Good | Satisfactory | Fair | 4966 | 53.9 |
May 2013 | Fair | Good | Satisfactory | Fair | 4966 | 53.9 |
May 2011 | Fair | Good | Satisfactory | Fair | 4966 | 53.9 |
May 2009 | Good | Good | Good | Good | 4966 | 64.0 |
November 2008 | Good | Good | Good | Good | 4966 | 64.0 |
September 2006 | Good | Good | Good | Good | 4774 | 64.1 |
September 2004 | Good | Good | Good | Good | 4774 | 63.7 |
October 2002 | Good | Good | Very Good | Good | 4635 | 63.8 |
October 2000 | Good | Good | Very Good | Good | 4500 | 63.8 |
September 1998 | Good | Good | Very Good | Good | 4500 | 63.8 |
May 1996 | Good | Good | Very Good | Good | 4500 | 79.5 |
April 1994 | Good | Good | Very Good | Good | 4500 | 79.6 |
May 1992 | Good | Good | Very Good | Good | 4500 | 79.6 |
January 1990 | Good | Good | Very Good | Good | 4300 | 79.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 630 | 616 | 7 | 7 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 5,300 | 5,180 | 120 | 0 | 0 |
Wearing Surfaces | sq. ft. | 5,300 | 5,300 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 10 | 10 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 109 | 0 | 109 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 109 | 109 | 0 | 0 | 0 |
Joints |
Other Joint | linear ft. | 84 | 84 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 252 | 126 | 126 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,563 | 157 | 1,093 | 0 | 313 |