Share:

BEAVER VALLEY EX over OHIO RIV,N&S RR, HAUL RD

Map

Coordinates:
+40.67908, -80.33152
40°40'45" N, 80°19'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BEAVER VALLEY EX over OHIO RIV,N&S RR, HAUL RD
Structure number:000000000003522
Old structure number:040060017000000 (from 1992 edition)
Location:VANPORT BRIDGE
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:714.9 ft. [217.9 m]
Total length:1767.1 ft. [538.6 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:69.2 ft. [21.1 m]
Vertical clearance above deck:20.3 ft. [6.2 m]
Vertical clearance below bridge:925.2 ft. [282.0 m]
Owner:State Highway Agency [01]
Year built:1970
Year reconstructed:2017
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:15,285 [as of 2016]
Truck traffic:8% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:None present but re-evaluation suggested [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:67.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,990,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairFairFairFair1528567.8
October 2015FairFairFairFair1612966.6
October 2014FairSatisfactoryFairFair1672967.3
October 2012FairSatisfactoryFairFair845873.6
October 2011FairSatisfactoryFairFair938928.1
2010Fair--Fair1528567.0
October 2010FairSatisfactoryFairFair913728.1
October 2009FairSatisfactoryFairFair1064428.1
October 2008FairSatisfactoryFairFair1453028.1
November 2007FairSatisfactoryFairFair2905828.1
October 2005FairSatisfactoryFairFair3248465.6
December 2003FairSatisfactoryFairFair3209965.6
December 2001FairSatisfactoryFairFair3868265.6
May 1999FairGoodSatisfactorySatisfactory3792471.6
April 1997FairGoodSatisfactorySatisfactory3718171.6
May 1995FairSatisfactorySatisfactorySatisfactory3202666.7
May 1993FairSatisfactoryFairSatisfactory2893955.7
December 1991FairSatisfactoryFairSatisfactory2893957.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.3,74803,74800
Steel Protective Coatingsq. ft.43,01343,013000
Steel Stringerlinear ft.15,731015,4762550
Steel Protective Coatingsq. ft.32,25932,259000
Deck
Reinforced Concrete Decksq. ft.122,6970122,69700
Superstructure
Steel Trusslinear ft.2,86002,5343260
Steel Protective Coatingsq. ft.32,25932,259000
Steel Floor Beamlinear ft.3,19003,0361540
Steel Protective Coatingsq. ft.53,76653,766000
Substructure
Reinforced Concrete Columneach64200
Reinforced Concrete Pier Walllinear ft.351187104600
Reinforced Concrete Abutmentlinear ft.18111022490
Reinforced Concrete Pier Caplinear ft.137136100
Joints
Compression Jointlinear ft.152015200
Other Jointlinear ft.138137100
Bearings
Movable Bearingeach56431300
Steel Protective Coatingsq. ft.64,51964,519000
Fixed Bearingeach2525000
Steel Protective Coatingsq. ft.32,25932,259000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5,2675,15794160