SR 2028,ENTERPRIZE over OVER PINE CREEK
Map
Coordinates:
+41.62006, -79.6373341°37'12" N, 79°38'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 2028,ENTERPRIZE over OVER PINE CREEK |
Structure number: | 000000000013270 |
Old structure number: | 202028001005330 (from 1992 edition) |
Location: | OIL CREEK TOWNSHIP |
Purpose: | Carries highway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 74.2 ft. [22.6 m] |
Total length: | 150.9 ft. [46.0 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 31.2 ft. [9.5 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1940 |
Year reconstructed: | 2013 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Box Beam or girders - Single or Spread [06] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,561 [as of 2016] |
Truck traffic: | 13% of total traffic |
Deck condition: | Excellent [9 out of 9] |
Superstructure condition: | Excellent [9 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 90.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $81,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Good | Excellent | Excellent | Very Good | 1561 | 90.0 |
November 2015 | Good | Excellent | Very Good | Very Good | 2095 | 88.4 |
November 2013 | Good | Excellent | Excellent | Very Good | 2087 | 72.5 |
November 2011 | Poor | Satisfactory | Serious | Satisfactory | 1666 | 11.9 |
November 2009 | Poor | Satisfactory | Serious | Satisfactory | 1930 | 9.9 |
November 2007 | Poor | Satisfactory | Serious | Satisfactory | 1929 | 9.9 |
November 2005 | Fair | Satisfactory | Fair | Satisfactory | 2159 | 64.2 |
November 2003 | Fair | Satisfactory | Fair | Satisfactory | 2043 | 66.4 |
January 2002 | Fair | Satisfactory | Fair | Satisfactory | 2152 | 66.2 |
November 1999 | Fair | Satisfactory | Fair | Satisfactory | 2117 | 66.3 |
October 1997 | Fair | Satisfactory | Fair | Satisfactory | 427 | 76.7 |
October 1995 | Fair | Satisfactory | Fair | Satisfactory | 2446 | 65.5 |
September 1993 | Fair | Satisfactory | Fair | Satisfactory | 2374 | 65.6 |
August 1991 | Fair | Fair | Fair | Satisfactory | 2341 | 61.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 608 | 608 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,672 | 4,672 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 4,088 | 4,088 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 50 | 50 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 92 | 92 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 292 | 292 | 0 | 0 | 0 |