Share:

T-513; MCKINLEY ST over I-81; SR 0081

Map

Coordinates:
+39.92020, -77.63928
39°55'13" N, 77°38'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:T-513; MCKINLEY ST over I-81; SR 0081
Structure number:000000000017383
Old structure number:282042001000000 (from 1992 edition)
Location:0.5ML. N. OF WAYNE AVE.
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:65.9 ft. [20.1 m]
Total length:200.1 ft. [61.0 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1963
Year reconstructed:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Other [9]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,312 [as of 2018]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:55.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,133,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018FairGoodFairSatisfactory431255.1
February 2016FairGoodFairSatisfactory433156.2
February 2014FairGoodFairSatisfactory424855.0
February 2012FairGoodFairSatisfactory430555.3
March 2010FairFairFairFair611554.3
March 2008FairGoodFairFair609155.4
March 2006FairGoodFairFair601652.2
January 2006FairGoodFairFair593149.7
April 2004FairSatisfactoryFairFair584949.8
April 2002FairVery GoodFairFair567749.9
April 2000FairSatisfactorySatisfactoryFair32062.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.1,5501,168743080
Deck
Reinforced Concrete Decksq. ft.6,4545,91853600
Wearing Surfacessq. ft.6,4546,454000
Substructure
Reinforced Concrete Columneach60420
Reinforced Concrete Abutmentlinear ft.7870800
Reinforced Concrete Pier Caplinear ft.1087127100
Joints
Strip Seal Jointlinear ft.9909900
Bearings
Elastomeric Bearingeach6464000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.400400000