Share:

US 22(ALT)(LR 175) over DELAWARE RIVER

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+40.69436, -75.20386
40°41'40" N, 75°12'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 22(ALT)(LR 175) over DELAWARE RIVER
Structure number:487302999200050
Location:CITY OF EASTON
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:299.9 ft. [91.4 m]
Total length:560.1 ft. [170.7 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Vertical clearance above deck:16.4 ft. [5.0 m]
Owner:Local Toll Authority [32]
Year built:1896
Year reconstructed:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Open Grating [3]

Latest Available Inspection: June 2008

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:31,769 [as of 1993]
Truck traffic:9% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:20.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2008FairGoodSatisfactoryGood3176920.5
June 1997FairVery GoodSatisfactoryGood3176966.0
June 1989PoorPoorPoorGood302142.0