SR 1004,PTRLM.CNTR over OVER OIL CREEK
Map
Coordinates:
+41.51681, -79.6827541°31'01" N, 79°40'58" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 1004,PTRLM.CNTR over OVER OIL CREEK |
Structure number: | 000000000033770 |
Old structure number: | 601004001001960 (from 1992 edition) |
Location: | CORNPLANTER TOWNSHIP |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 117.1 ft. [35.7 m] |
Total length: | 238.9 ft. [72.8 m] |
Roadway width between curbs: | 15.4 ft. [4.7 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Vertical clearance above deck: | 17.1 ft. [5.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 1884 |
Year reconstructed: | 1984 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Truss - Thru [10] |
Deck type: | Open Grating [3] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 76 [as of 2016] |
Truck traffic: | 3% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 42.9 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $1,517,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Poor | Fair | Serious | Fair | 76 | 42.9 |
September 2015 | Poor | Fair | Serious | Fair | 134 | 34.8 |
September 2013 | Poor | Fair | Serious | Fair | 93 | 38.9 |
September 2011 | Poor | Fair | Serious | Fair | 141 | 33.3 |
September 2009 | Poor | Fair | Serious | Fair | 142 | 33.7 |
September 2008 | Poor | Fair | Serious | Fair | 142 | 33.7 |
October 2007 | Poor | Fair | Poor | Fair | 184 | 42.8 |
September 2006 | Poor | Fair | Poor | Fair | 181 | 23.0 |
September 2005 | Poor | Fair | Poor | Fair | 178 | 23.0 |
September 2004 | Poor | Fair | Poor | Fair | 178 | 23.0 |
September 2003 | Poor | Fair | Poor | Fair | 162 | 23.1 |
October 2002 | Poor | Fair | Poor | Fair | 159 | 23.1 |
September 2001 | Poor | Fair | Poor | Fair | 157 | 23.1 |
September 2000 | Poor | Fair | Poor | Fair | 157 | 23.1 |
October 1999 | Poor | Fair | Poor | Fair | 157 | 17.0 |
October 1998 | Poor | Fair | Poor | Fair | 201 | 22.8 |
October 1997 | Poor | Fair | Poor | Fair | 197 | 22.9 |
October 1996 | Poor | Fair | Poor | Fair | 193 | 22.9 |
August 1995 | Poor | Fair | Poor | Fair | 189 | 23.6 |
September 1994 | Poor | Fair | Poor | Fair | 186 | 23.5 |
August 1993 | Poor | Fair | Poor | Fair | 184 | 21.2 |
July 1992 | Poor | Fair | Poor | Fair | 184 | 21.2 |
August 1991 | Poor | Satisfactory | Poor | Fair | 179 | 21.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 1,154 | 578 | 556 | 20 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Steel Truss | linear ft. | 462 | 231 | 225 | 6 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 202 | 102 | 100 | 0 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Substructure |
Masonry Pier Wall | linear ft. | 39 | 0 | 39 | 0 | 0 |
Masonry Abutment | linear ft. | 119 | 50 | 69 | 0 | 0 |
Deck |
Open Grid Deck | sq. ft. | 3,740 | 1,870 | 1,870 | 0 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 4 | 4 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Fixed Bearing | each | 4 | 4 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 470 | 236 | 234 | 0 | 0 |
Steel Protective Coating | sq. ft. | 21,506 | 21,506 | 0 | 0 | 0 |