SR 6008,CENTER ST. over OVER OIL CREEK
Map
Coordinates:
+41.43393, -79.7096141°26'02" N, 79°42'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 6008,CENTER ST. over OVER OIL CREEK |
Structure number: | 000000000033654 |
Old structure number: | 606008007000800 (from 1992 edition) |
Location: | OIL CITY |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 172.9 ft. [52.7 m] |
Total length: | 178.2 ft. [54.3 m] |
Roadway width between curbs: | 34.5 ft. [10.5 m] |
Deck width edge-to-edge: | 35.8 ft. [10.9 m] |
Vertical clearance above deck: | 17.7 ft. [5.4 m] |
Owner: | State Highway Agency [01] |
Year built: | 1939 |
Year reconstructed: | 1985 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Arch - Thru [12] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,694 [as of 2017] |
Truck traffic: | 11% of total traffic |
Deck condition: | Excellent [9 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 81.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $660,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Excellent | Satisfactory | Good | 6694 | 81.4 |
September 2015 | Poor | Satisfactory | Serious | Fair | 6810 | 43.2 |
September 2013 | Poor | Satisfactory | Serious | Fair | 6456 | 43.1 |
September 2011 | Poor | Satisfactory | Poor | Fair | 601 | 58.1 |
September 2009 | Poor | Satisfactory | Poor | Fair | 608 | 56.1 |
December 2008 | Poor | Satisfactory | Poor | Fair | 648 | 56.1 |
September 2007 | Poor | Satisfactory | Poor | Fair | 648 | 65.3 |
September 2005 | Poor | Satisfactory | Poor | Fair | 629 | 65.1 |
August 2004 | Poor | Satisfactory | Poor | Fair | 629 | 65.1 |
September 2003 | Fair | Satisfactory | Fair | Fair | 11109 | 78.0 |
October 2001 | Fair | Satisfactory | Fair | Fair | 10815 | 76.0 |
October 2000 | Fair | Satisfactory | Fair | Fair | 10815 | 78.0 |
September 1999 | Fair | Satisfactory | Fair | Fair | 10603 | 78.0 |
October 1997 | Fair | Satisfactory | Fair | Fair | 10375 | 78.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 1,046 | 1,046 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 6,623 | 6,623 | 0 | 0 | 0 |
Superstructure |
Steel Arch | linear ft. | 344 | 344 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 342 | 342 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Substructure |
Masonry Abutment | linear ft. | 111 | 111 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 76 | 76 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 2 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Fixed Bearing | each | 2 | 2 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Bridge Rail |