Share:

KEYS BRIDGE TR 719 over RACCOON CREEK

Map

Coordinates:
+40.37120, -80.36470
40°22'16" N, 80°21'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KEYS BRIDGE TR 719 over RACCOON CREEK
Structure number:000000000035333
Old structure number:627224082140280 (from 1992 edition)
Location:300' WEST OF SR 4075
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:58.1 ft. [17.7 m]
Total length:61.0 ft. [18.6 m]
Roadway width between curbs:12.1 ft. [3.7 m]
Deck width edge-to-edge:13.8 ft. [4.2 m]
Owner:County Highway Agency [02]
Year built:1903
Year reconstructed:2017
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:80 [as of 1993]
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:20.5
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$394,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017PoorFairPoorFair8020.5
August 2015PoorFairPoorFair8020.5
August 2013PoorFairPoorFair8020.5
August 2011PoorFairSeriousSerious8020.5
August 2009PoorSatisfactorySeriousPoor8021.5
June 2009PoorPoorPoorFair8018.2
August 2007PoorFairPoorFair8020.5
August 2005PoorFairPoorFair8020.5
September 2003PoorFairPoorFair8020.5
September 2001PoorFairPoorFair8020.5
December 1999FairSatisfactorySatisfactoryFair8023.6
September 1997PoorGoodGoodPoor8023.6
October 1995PoorPoorImminent FailurePoor8020.5
November 1993PoorPoorCriticalPoor4018.6
September 1991PoorGoodPoorSatisfactory4022.8