Share:

PR 109 over ESPINO CREEK

Map

Coordinates:
+18.28077, -68.07683
18°16'51" N, 68°04'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 109 over ESPINO CREEK
Structure number:002201
Location:3 KM EAST OF AÑASCO
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:30.8 ft. [9.4 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:19.0 ft. [5.8 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:State Highway Agency [01]
Year built:1927
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,500 [as of 2005]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:62.7
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$167,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2018FairFairFairFair250062.7
December 2016FairFairFairFair250062.7
December 2014FairFairFairFair250062.7
November 2012FairFairFairFair250062.1
December 2010FairFairFairSatisfactory250062.7
November 2008FairFairFairSatisfactory250062.7
June 2007FairFairFairSatisfactory230064.0
September 2005FairFairFairSatisfactory230042.2
October 2003FairFairFairSatisfactory230042.2
September 2001PoorPoorFairSatisfactory230040.0
January 1999FairFairSatisfactorySatisfactory630048.4
May 1996FairFairSatisfactorySatisfactory560048.7
July 1994FairFairFairSatisfactory530037.0
July 1992FairSatisfactoryFairFair530038.3
February 1991FairFairFairFair26046.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1871285900
Steel Protective Coatingsq. ft.9905382691830
Deck
Prestressed Concrete Decksq. ft.1,0013443662910
Wearing Surfacessq. ft.59246312900
Substructure
Reinforced Concrete Abutmentlinear ft.115763900
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.56361370