Share:

PR 156 over BARRANQUITAS RIVER

Map

Coordinates:
+18.18833, -66.31500
18°11'18" N, 66°18'54" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 156 over BARRANQUITAS RIVER
Structure number:003371
Location:2 KM WEST OF BARRANQUITAS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:32.8 ft. [10.0 m]
Total length:36.1 ft. [11.0 m]
Roadway width between curbs:24.3 ft. [7.4 m]
Deck width edge-to-edge:32.8 ft. [10.0 m]
Owner:State Highway Agency [01]
Year built:1911
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:8,100 [as of 2002]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:38.4
Recommended work:Replacement of bridge or other structure because of relocation of road. [32]
Estimated cost of work:$146,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairFairFairFair810038.4
May 2015FairFairFairFair810039.3
May 2013FairFairFairFair810039.3
May 2011FairFairFairFair820038.3
May 2009FairFairFairFair810040.9
May 2007FairFairFairFair810040.9
February 2005FairFairFairFair790036.3
October 2002FairFairFairFair790036.3
June 2001FairFairFairFair710035.2
April 1999FairFairSatisfactoryFair480039.6
February 1997FairFairSatisfactorySatisfactory570047.2
March 1995FairFairSatisfactorySatisfactory600047.1
February 1993FairSatisfactoryFairFair570036.3
November 1991FairSatisfactoryFairFair570036.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.459213164820
Steel Protective Coatingsq. ft.1,5077005382690
Deck
Reinforced Concrete Decksq. ft.1,3451,07626900
Wearing Surfacessq. ft.1,0761,076000
Substructure
Reinforced Concrete Abutmentlinear ft.1313000
Masonry Abutmentlinear ft.5205200
Reinforced Concrete Pile Cap/Footinglinear ft.6666000
Bearings
Movable Bearingeach106220
Fixed Bearingeach106220
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9292000
Steel Protective Coatingsq. ft.301301000