Share:

PR 176 over LAS CURÍAS CREEK

Map

Coordinates:
+18.34361, -66.05679
18°20'37" N, 66°03'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 176 over LAS CURÍAS CREEK
Structure number:003991
Location:7 KM S E OF GUAYNABO
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:33.1 ft. [10.1 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:16.4 ft. [5.0 m]
Deck width edge-to-edge:20.3 ft. [6.2 m]
Owner:State Highway Agency [01]
Year built:1936
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: 2081

Good/Fair/Poor Condition:Poor
Average daily traffic:170 [as of 200]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Sufficiency rating:485.0
Estimated cost of work:$400,004,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
2081Poor6 out of 10170485.0
September 2018PoorN out of 10170048.5
August 2017PoorN out of 10170048.5
August 2016PoorN out of 10170048.5
July 2015PoorN out of 10426847.6
July 2014PoorN out of 10170048.5
July 2013PoorN out of 10170048.5
July 2012PoorN out of 10170048.5
August 2010PoorN out of 10170048.5
April 2008PoorN out of 10170048.5
August 2006PoorN out of 10170015.9
February 2004PoorN out of 10170015.9
April 2001PoorN out of 10160016.2
January 2000PoorN out of 10160016.2
June 1999PoorN out of 10160016.2
March 1997PoorN out of 10330019.6
February 1995PoorN out of 10190020.0
February 1993PoorN out of 10190026.4
July 1991PoorN out of 10190027.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.167105331613
Steel Protective Coatingsq. ft.74363586220
Deck
Reinforced Concrete Decksq. ft.678215420430
Wearing Surfacessq. ft.549549000
Substructure
Reinforced Concrete Abutmentlinear ft.95821300
Reinforced Concrete Pile Cap/Footinglinear ft.2002000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.663620100