Share:

PR 200R over WATERWAY

Map

Coordinates:
+18.25235, -65.73573
18°15'08" N, 65°44'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 200R over WATERWAY
Structure number:010871
Location:IN ISABEL II, VIEQUES
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:19.7 ft. [6.0 m]
Total length:51.2 ft. [15.6 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:31.2 ft. [9.5 m]
Owner:State Highway Agency [01]
Year built:1930
Year reconstructed:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:7,300 [as of 2005]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:44.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$44,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018FairFairFairSatisfactory730044.3
January 2016FairFairFairSatisfactory730044.3
January 2014FairFairFairSatisfactory730044.3
January 2012FairFairSatisfactorySatisfactory730057.0
January 2010FairFairSatisfactorySatisfactory730057.0
August 2007FairSatisfactorySatisfactorySatisfactory720059.0
June 2005FairSatisfactorySatisfactorySatisfactory660061.0
March 2002FairSatisfactorySatisfactorySatisfactory20073.2
March 1999FairSatisfactorySatisfactorySatisfactory20081.9
November 1996FairSatisfactorySatisfactorySatisfactory20081.9
December 1994FairSatisfactorySatisfactorySatisfactory20081.0
December 1992FairFairFairSatisfactory20068.7
January 1991FairFairFairSatisfactory250044.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Deck
Prestressed Concrete Decksq. ft.8077426500
Wearing Surfacessq. ft.50639810800
Superstructure
Reinforced Concrete Archlinear ft.2013700
Substructure
Masonry Abutmentlinear ft.2320300
Reinforced Concrete Pile Cap/Footinglinear ft.77000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3939000