Share:

16 STREET over BUENA VISTA CREEK

Map

Coordinates:
+18.39610, -66.06821
18°23'46" N, 66°04'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:16 STREET over BUENA VISTA CREEK
Structure number:021251
Location:VILLA NEVAREZ RIO PIEDRAS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:24.6 ft. [7.5 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:26.6 ft. [8.1 m]
Deck width edge-to-edge:42.7 ft. [13.0 m]
Skew angle:11°
Owner:City or Municipal Highway Agency [04]
Year built:1950
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,350 [as of 2005]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:72.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$250,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairFairFairSatisfactory135072.8
May 2016FairFairFairSatisfactory135072.8
May 2014FairFairFairSatisfactory135072.8
June 2012FairFairFairSatisfactory135072.8
July 2010FairFairFairSatisfactory135073.8
May 2008FairFairFairSatisfactory135073.8
August 2006FairSatisfactorySatisfactorySatisfactory135061.6
August 2004FairSatisfactorySatisfactorySatisfactory135061.6
August 2002FairSatisfactorySatisfactorySatisfactory135061.6
July 2000FairSatisfactorySatisfactorySatisfactory135061.6
December 1998FairGoodSatisfactorySatisfactory135061.6
August 1996FairGoodFairSatisfactory135051.5
October 1994FairSatisfactorySatisfactorySatisfactory120061.5
October 1992FairSatisfactorySatisfactorySatisfactory200061.4
February 1991FairFairFairFair200051.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Deck
Reinforced Concrete Decksq. ft.1,1521847532150
Wearing Surfacessq. ft.7211393342480
Substructure
Reinforced Concrete Abutmentlinear ft.89791000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.590301613