RI 113 MAIN AV over AMTRAK
Map
Coordinates:
+41.71140, -71.4479241°42'41" N, 71°26'53" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RI 113 MAIN AV over AMTRAK |
Structure number: | 000000000000020 |
Location: | 1.0 Mi E of JCT I-95 |
Purpose: | Carries highway and pedestrian walkway over railroad |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 78.4 ft. [23.9 m] |
Total length: | 82.4 ft. [25.1 m] |
Roadway width between curbs: | 65.0 ft. [19.8 m] |
Deck width edge-to-edge: | 81.0 ft. [24.7 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Skew angle: | 11° |
Owner: | State Highway Agency [01] |
Year built: | 2006 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 34,118 [as of 2015] |
Truck traffic: | 2% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 91.5 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $10,820,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Fair | Good | Satisfactory | Good | 34118 | 91.5 |
October 2015 | Good | Good | Good | Good | 34118 | 88.0 |
October 2013 | Good | Good | Good | Good | 28400 | 89.2 |
November 2011 | Good | Good | Good | Good | 28400 | 87.2 |
November 2009 | Good | Good | Good | Good | 28400 | 92.2 |
November 2007 | Good | Very Good | Very Good | Very Good | 28400 | 92.2 |
February 2007 | Good | Very Good | Very Good | Very Good | 28400 | 92.2 |
July 2001 | Poor | Poor | Poor | Poor | 24000 | 41.0 |
March 1999 | Poor | Poor | Poor | Poor | 24000 | 41.0 |
February 1997 | Poor | Poor | Poor | Poor | 20300 | 39.4 |
April 1995 | Poor | Poor | Poor | Poor | 20300 | 40.2 |
April 1993 | Poor | Poor | Poor | Poor | 20300 | 40.2 |
August 1991 | Poor | Poor | Poor | Poor | 20300 | 40.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 1,771 | 859 | 910 | 2 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 6,360 | 6,360 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 5,240 | 5,240 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 165 | 148 | 17 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 83 | 83 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 141 | 129 | 12 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 44 | 32 | 12 | 0 | 0 |
Bridge Rail |
Other Material Bridge Rail | linear ft. | 218 | 180 | 36 | 2 | 0 |