RI 37 EB over RAMP A
Map
Coordinates:
+41.74866, -71.4454041°44'55" N, 71°26'43" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RI 37 EB over RAMP A |
Structure number: | 000000000006300 |
Location: | 0.8 Mi E of PONTIAC AV |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 56.1 ft. [17.1 m] |
Total length: | 61.0 ft. [18.6 m] |
Roadway width between curbs: | 39.0 ft. [11.9 m] |
Deck width edge-to-edge: | 44.9 ft. [13.7 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 4° |
Owner: | State Highway Agency [01] |
Year built: | 1966 |
Year reconstructed: | 1989 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 33,046 [as of 2015] |
Truck traffic: | 2% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 74.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $2,790,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 33046 | 74.0 |
June 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 33046 | 74.0 |
July 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 6300 | 86.0 |
July 2011 | Fair | Good | Satisfactory | Satisfactory | 22000 | 76.3 |
August 2009 | Fair | Good | Good | Satisfactory | 22000 | 76.3 |
August 2007 | Good | Good | Good | Good | 22000 | 76.3 |
July 2005 | Good | Good | Good | Good | 20000 | 62.9 |
March 2003 | Fair | Good | Good | Satisfactory | 20000 | 62.9 |
March 2001 | Fair | Good | Good | Satisfactory | 20000 | 62.9 |
February 1999 | Fair | Good | Good | Satisfactory | 20000 | 62.9 |
June 1997 | Good | Good | Good | Good | 20000 | 62.9 |
January 1997 | Fair | Good | Good | Satisfactory | 22400 | 74.1 |
January 1995 | Poor | Good | Satisfactory | Poor | 22400 | 43.9 |
January 1993 | Poor | Good | Satisfactory | Poor | 22400 | 48.0 |
July 1991 | Fair | Good | Good | Satisfactory | 22400 | 75.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 392 | 163 | 227 | 2 | 0 |
Steel Protective Coating | sq. ft. | 3,280 | 3,210 | 0 | 0 | 70 |
Deck |
Reinforced Concrete Deck | sq. ft. | 2,743 | 2,279 | 452 | 12 | 0 |
Wearing Surfaces | sq. ft. | 2,379 | 2,379 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 89 | 15 | 28 | 46 | 0 |
Joints |
Pourable Joint | linear ft. | 78 | 78 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 7 | 4 | 1 | 2 | 0 |
Steel Protective Coating | sq. ft. | 21 | 14 | 0 | 0 | 7 |
Fixed Bearing | each | 7 | 0 | 5 | 2 | 0 |
Steel Protective Coating | sq. ft. | 21 | 9 | 5 | 0 | 7 |
Bridge Rail |
Other Material Bridge Rail | linear ft. | 122 | 45 | 17 | 60 | 0 |