RI 402 FRNCHTWN RD over Ramp 4E to RI 402,RI 4
Map
Coordinates:
+41.62797, -71.4871741°37'41" N, 71°29'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RI 402 FRNCHTWN RD over Ramp 4E to RI 402,RI 4 |
Structure number: | 000000000007630 |
Location: | 0.5 Mi E of JCT RI 2 |
Purpose: | Carries highway and pedestrian walkway over highway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 120.1 ft. [36.6 m] |
Total length: | 362.9 ft. [110.6 m] |
Roadway width between curbs: | 67.9 ft. [20.7 m] |
Deck width edge-to-edge: | 80.4 ft. [24.5 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 5° |
Owner: | State Highway Agency [01] |
Year built: | 1973 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: July 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,423 [as of 2015] |
Truck traffic: | 3% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 44.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $8,481,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2017 | Poor | Fair | Fair | Poor | 13423 | 44.4 |
July 2015 | Poor | Fair | Fair | Poor | 13423 | 25.8 |
July 2013 | Fair | Fair | Fair | Satisfactory | 16700 | 44.4 |
July 2011 | Fair | Fair | Fair | Good | 16700 | 72.0 |
September 2009 | Fair | Satisfactory | Fair | Good | 16700 | 75.4 |
February 2008 | Poor | Satisfactory | Poor | Fair | 16200 | 56.4 |
January 2006 | Poor | Satisfactory | Poor | Fair | 18810 | 54.9 |
July 2003 | Poor | Satisfactory | Serious | Fair | 18810 | 37.0 |
September 2001 | Poor | Satisfactory | Serious | Fair | 18810 | 37.0 |
August 1999 | Poor | Satisfactory | Serious | Fair | 11100 | 42.4 |
May 1997 | Poor | Good | Poor | Satisfactory | 11100 | 62.4 |
June 1995 | Poor | Good | Poor | Satisfactory | 10200 | 65.8 |
November 1993 | Poor | Satisfactory | Poor | Fair | 10200 | 65.8 |
December 1991 | Poor | Satisfactory | Poor | Fair | 10200 | 67.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 3,619 | 2,239 | 500 | 880 | 0 |
Steel Protective Coating | sq. ft. | 43,428 | 10,928 | 0 | 32,500 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 29,213 | 26,919 | 1,768 | 526 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 2 | 4 | 2 | 0 |
Reinforced Concrete Abutment | linear ft. | 183 | 0 | 182 | 1 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 155 | 42 | 87 | 26 | 0 |
Joints |
Pourable Joint | linear ft. | 150 | 0 | 150 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 20 | 17 | 3 | 0 | 0 |
Movable Bearing | each | 20 | 18 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 500 | 500 | 0 | 0 | 0 |
Bridge Rail |
Other Material Bridge Rail | linear ft. | 726 | 656 | 70 | 0 | 0 |