RI 138 over WEST PASSAGE NARRA BAY
Map
Coordinates:
+41.52833, -71.4027641°31'42" N, 71°24'10" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RI 138 over WEST PASSAGE NARRA BAY |
Structure number: | 000000000008000 |
Location: | 2.0 Mi E of JCT US 1 |
Purpose: | Carries highway and pedestrian walkway over highway and waterway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 636.2 ft. [193.9 m] |
Total length: | 7353.4 ft. [2241.2 m] |
Roadway width between curbs: | 64.0 ft. [19.5 m] |
Deck width edge-to-edge: | 74.2 ft. [22.6 m] |
Vertical clearance below bridge: | 134.5 ft. [41.0 m] |
Owner: | State Toll Authority [31] |
Year built: | 1992 |
Year reconstructed: | 2009 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 23 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Segmental box girder [21] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 33,533 [as of 2015] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 83.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $184,006,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 33533 | 83.4 |
May 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 33533 | 83.4 |
May 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 30000 | 83.1 |
July 2011 | Fair | Fair | Good | Satisfactory | 30000 | 82.1 |
May 2011 | Fair | Satisfactory | Good | Satisfactory | 30000 | 83.1 |
May 2009 | Fair | Fair | Good | Fair | 30000 | 71.5 |
August 2006 | Fair | Fair | Fair | Fair | 30000 | 71.5 |
September 2001 | Poor | Poor | Fair | Satisfactory | 28735 | 64.3 |
May 2000 | Fair | Fair | Fair | Satisfactory | 28735 | 66.3 |
August 1999 | Fair | Good | Satisfactory | Good | 28735 | 78.3 |
October 1993 | Good | Good | Good | Good | 17400 | 96.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 21,413 | 20,268 | 1,108 | 37 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 177,822 | 142,258 | 35,564 | 0 | 0 |
Wearing Surfaces | sq. ft. | 148,986 | 0 | 148,986 | 0 | 0 |
Prestressed Concrete Top Flange | sq. ft. | 456,010 | 454,010 | 1,991 | 9 | 0 |
Wearing Surfaces | sq. ft. | 456,010 | 453,910 | 2,001 | 99 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 1,966 | 1,119 | 197 | 650 | 0 |
Reinforced Concrete Abutment | linear ft. | 152 | 116 | 28 | 8 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 830 | 473 | 352 | 5 | 0 |
Steel Pile | each | 328 | 112 | 200 | 16 | 0 |
Steel Protective Coating | sq. ft. | 50,450 | 50,409 | 0 | 0 | 41 |
Prestressed Concrete Pile | each | 253 | 13 | 240 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 2,107 | 2,023 | 42 | 42 | 0 |
Joints |
Assembly with Seal | each | 592 | 513 | 0 | 69 | 10 |
Assembly without Seal Joint | linear ft. | 296 | 271 | 25 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 522 | 18 | 484 | 9 | 11 |
Pot Bearing | each | 48 | 33 | 13 | 2 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 14,706 | 14,397 | 18 | 291 | 0 |
Steel Protective Coating | sq. ft. | 60,000 | 42,500 | 7,875 | 6,500 | 3,125 |