Share:

NICHOLAS RD over ROARING BROOK

Map

Coordinates:
+41.68138, -71.77192
41°40'53" N, 71°46'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NICHOLAS RD over ROARING BROOK
Structure number:000000000008460
Location:1.0 Mi W of JCT Lws Fm Rd
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:28.9 ft. [8.8 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:15.7 ft. [4.8 m]
Deck width edge-to-edge:16.4 ft. [5.0 m]
Owner:Town or Township Highway Agency [03]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:700 [as of 2008]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:20.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$446,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018PoorFairPoorFair70020.7
August 2016PoorFairPoorFair70024.8
June 2015PoorPoorPoorFair70022.5
August 2014PoorFairPoorFair70024.8
September 2012FairFairFairFair70035.2
September 2010FairFairFairFair70042.2
October 2008FairFairFairFair70042.2
January 2008FairFairFairFair70051.1
April 2006FairFairFairFair40051.3
January 2004FairSatisfactoryFairFair40049.7
February 2002FairSatisfactoryFairFair40049.6
December 1999FairSatisfactoryFairFair40049.6
September 1997FairSatisfactoryFairSatisfactory40050.7
October 1995FairGoodFairSatisfactory50050.8
August 1994FairGoodFairSatisfactory50050.8
September 1993FairGoodFairSatisfactory50050.8
December 1991FairGoodGoodSatisfactory50062.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.16101014020
Steel Protective Coatingsq. ft.6808000600
Deck
Reinforced Concrete Decksq. ft.527382120250
Wearing Surfacessq. ft.5024426000
Substructure
Masonry Abutmentlinear ft.3302760
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.64312670
Steel Protective Coatingsq. ft.128860042