Share:

POINT ST over PROVIDENCE RIVER

Map

Coordinates:
+41.81801, -71.40357
41°49'05" N, 71°24'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:POINT ST over PROVIDENCE RIVER
Structure number:000000000009800
Location:0.2 Mi E of Eddy St
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:107.9 ft. [32.9 m]
Total length:527.9 ft. [160.9 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance above deck:16.4 ft. [5.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1927
Year reconstructed:1999
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Movable - Swing [17]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:23,254 [as of 2015]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:In place but in a deteriorated condition [3]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:43.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$9,266,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017FairGoodFairSatisfactory2325443.1
December 2015FairGoodFairSatisfactory2325447.4
December 2013FairGoodFairSatisfactory2500051.5
December 2011FairVery GoodFairGood2080081.9
December 2009FairVery GoodFairGood2080062.0
February 2008FairVery GoodSatisfactoryGood2080073.5
February 2006FairVery GoodSatisfactoryGood2205773.3
September 2004FairVery GoodSatisfactoryGood2205791.9
February 2002FairVery GoodSatisfactoryGood2205791.9
February 2000PoorVery GoodPoorGood2080064.1
October 1997PoorPoorPoorFair-44.2
October 1995PoorPoorPoorFair2250033.7
September 1994PoorPoorPoorSatisfactory2250033.7
September 1993PoorPoorPoorFair2250034.9
September 1992PoorSeriousSeriousFair1050048.0
April 1990PoorSeriousSeriousFair1050048.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,4551,4401500
Steel Protective Coatingsq. ft.13,05412,9797500
Steel Stringerlinear ft.3,0022,4024501473
Steel Protective Coatingsq. ft.24,01623,86615000
Deck
Reinforced Concrete Decksq. ft.20,59220,592000
Wearing Surfacessq. ft.20,59220,41118100
Superstructure
Steel Trusslinear ft.5522292061170
Steel Protective Coatingsq. ft.4,2003,2001,00000
Steel Floor Beamlinear ft.60749176382
Steel Protective Coatingsq. ft.6,0705,9957500
Steel Gusset Plateeach1324768170
Steel Protective Coatingsq. ft.10,56010,06050000
Substructure
Masonry Pier Walllinear ft.35023768450
Masonry Abutmentlinear ft.122388400
Reinforced Concrete Pile Cap/Footinglinear ft.3838000
Reinforced Concrete Pier Caplinear ft.3503381200
Joints
Strip Seal Jointlinear ft.1200151050
Pourable Jointlinear ft.120606000
Assembly without Seal Jointlinear ft.3903900
Bearings
Movable Bearingeach3603330
Steel Protective Coatingsq. ft.7266600
Fixed Bearingeach1613120
Steel Protective Coatingsq. ft.3232000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,05655050600
Steel Protective Coatingsq. ft.2,1201,62050000